MII IG Kerndatensatz-Modul Bildgebung
2027.0.0-ballot.1 -
Germany
This page is part of the MII Implementation Guide Bildgebung (v2027.0.0-ballot.1: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
{
"resourceType" : "ImagingStudy",
"id" : "mii-exa-bildgebung-bildgebungsstudie-ct",
"meta" : {
"profile" : [
🔗 "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-pr-bildgebung-bildgebungsstudie"
]
},
"language" : "de",
"text" : {
"status" : "extensions",
"div" : "<div xml:lang=\"de\" lang=\"de\"><hr/><p><b>German</b></p><hr/><p class=\"res-header-id\"><b>Generated Narrative: ImagingStudy mii-exa-bildgebung-bildgebungsstudie-ct</b></p><a name=\"de-mii-exa-bildgebung-bildgebungsstudie-ct\"> </a><a name=\"de-hcmii-exa-bildgebung-bildgebungsstudie-ct\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-mii-pr-bildgebung-bildgebungsstudie.html\">MII PR Bildgebung Bildgebungsstudie</a></p></div><p><b>MII EX Bildgebung Bildgebungsgrund</b>: Verdacht auf Karzinom</p><p><b>status</b>: Available</p><p><b>modality</b>: <a href=\"http://hl7.org/fhir/R4/codesystem-dicom-dcim.html#dicom-dcim-CT\">DICOM: CT</a> (Computed Tomography)</p><p><b>subject</b>: <a href=\"Patient-mii-exa-bildgebung-radiologischer-patient.html\">Erika Beispielpatientin Female, DoB: 1970-01-01</a></p><p><b>encounter</b>: <a href=\"Encounter-mii-exa-bildgebung-radiologischer-fall.html\">Encounter: status = finished; class = AMB (AMB)</a></p><p><b>basedOn</b>: <a href=\"ServiceRequest-mii-exa-bildgebung-anforderung-bildgebung.html\">ServiceRequest Mammography (procedure)</a></p><p><b>numberOfSeries</b>: 2</p><p><b>numberOfInstances</b>: 390</p><p><b>procedureReference</b>: <a href=\"Procedure-mii-exa-bildgebung-bildgebungsprozedur.html\">Procedure Screening mammography of bilateral breasts (procedure)</a></p><p><b>reasonReference</b>: <a href=\"Condition-mii-exa-bildgebung-radiologische-diagnose.html\">Condition </a></p><p><b>description</b>: whole body aquisition</p><blockquote><p><b>series</b></p><blockquote><p><b>MII EX Bildgebung Modalität CT</b></p><ul><li>convolutionalKernel: SOFT</li><li>CTDIvol: 4.04 milligray</li><li>KVP: 110 kilovolt</li><li>exposure: 38 milliampere second</li><li>exposureTime: 600 milliseconds</li><li>xRayTubeCurrent: 96 milliampere</li></ul></blockquote><blockquote><p><b>MII EX Bildgebung Kontrastmittel</b></p><ul><li>contrastBolus: true</li><li>contrastBolusDetails: <a href=\"MedicationAdministration-mii-exa-bildgebung-kontrastmittelgabe.html\">MedicationAdministration: status = completed; medication[x] = ->Medication Iopromide; effective[x] = 2024-07-19 12:21:45+0200 --> 2024-07-19 12:22:45+0200</a></li></ul></blockquote><p><b>uid</b>: series-example-uid</p><p><b>number</b>: 1</p><p><b>modality</b>: <a href=\"http://hl7.org/fhir/R4/codesystem-dicom-dcim.html#dicom-dcim-CT\">DICOM: CT</a> (Computed Tomography)</p><p><b>description</b>: AC LD CT Whole Body 4.0 HD Field of View</p><p><b>numberOfInstances</b>: 195</p><p><b>bodySite</b>: <a href=\"http://snomed.info/id/51185008\">SNOMED CT: 51185008</a> (Thoracic structure (body structure)) (version = http://snomed.info/sct/900000000000207008/version/20260701 )</p><p><b>laterality</b>: <a href=\"http://snomed.info/id/7771000\">SNOMED CT: 7771000</a> (Left) (version = http://snomed.info/sct/900000000000207008/version/20260701 )</p><p><b>started</b>: 2024-07-19 12:03:30+0200</p><h3>Performers</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Actor</b></td></tr><tr><td style=\"display: none\">*</td><td><a href=\"Device-mii-exa-bildgebung-geraet.html\">Device: manufacturer = Siemens</a></td></tr></table><h3>Instances</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Extension</b></td><td><b>Uid</b></td><td><b>SopClass</b></td><td><b>Number</b></td></tr><tr><td style=\"display: none\">*</td><td/><td>instance-example-uid</td><td>unknown: urn:oid:1.2.840.10008.5.1.4.1.1.2 (urn:oid:1.2.840.10008.5.1.4.1.1.2)</td><td>31</td></tr></table></blockquote></div>"
},
"extension" : [
{
"url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-bildgebungsgrund",
"valueString" : "Verdacht auf Karzinom"
}
],
"status" : "available",
"modality" : [
{
"system" : "http://dicom.nema.org/resources/ontology/DCM",
"code" : "CT",
"display" : "Computed Tomography"
}
],
"subject" : {
🔗 "reference" : "Patient/mii-exa-bildgebung-radiologischer-patient",
"identifier" : {
"type" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0203",
"code" : "MR",
"display" : "Medical record number"
}
]
},
"system" : "https://system-url",
"value" : "study-uid"
}
},
"encounter" : {
🔗 "reference" : "Encounter/mii-exa-bildgebung-radiologischer-fall"
},
"basedOn" : [
{
🔗 "reference" : "ServiceRequest/mii-exa-bildgebung-anforderung-bildgebung"
}
],
"numberOfSeries" : 2,
"numberOfInstances" : 390,
"procedureReference" : {
🔗 "reference" : "Procedure/mii-exa-bildgebung-bildgebungsprozedur"
},
"reasonReference" : [
{
🔗 "reference" : "Condition/mii-exa-bildgebung-radiologische-diagnose"
}
],
"description" : "whole body aquisition",
"series" : [
{
"extension" : [
{
"extension" : [
{
"url" : "convolutionalKernel",
"valueString" : "SOFT"
},
{
"url" : "CTDIvol",
"valueQuantity" : {
"value" : 4.04,
"unit" : "milligray"
}
},
{
"url" : "KVP",
"valueQuantity" : {
"value" : 110,
"unit" : "kilovolt"
}
},
{
"url" : "exposure",
"valueQuantity" : {
"value" : 38,
"unit" : "milliampere second"
}
},
{
"url" : "exposureTime",
"valueQuantity" : {
"value" : 600,
"unit" : "milliseconds"
}
},
{
"url" : "xRayTubeCurrent",
"valueQuantity" : {
"value" : 96,
"unit" : "milliampere"
}
}
],
"url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-modalitaet-ct"
},
{
"extension" : [
{
"url" : "contrastBolus",
"valueBoolean" : true
},
{
"url" : "contrastBolusDetails",
"valueReference" : {
🔗 "reference" : "MedicationAdministration/mii-exa-bildgebung-kontrastmittelgabe"
}
}
],
"url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-kontrastmittel"
}
],
"uid" : "series-example-uid",
"number" : 1,
"modality" : {
"system" : "http://dicom.nema.org/resources/ontology/DCM",
"code" : "CT",
"display" : "Computed Tomography"
},
"description" : "AC LD CT Whole Body 4.0 HD Field of View",
"numberOfInstances" : 195,
"bodySite" : {
"system" : "http://snomed.info/sct",
"version" : "http://snomed.info/sct/900000000000207008/version/20260701",
"code" : "51185008",
"display" : "Thoracic structure (body structure)"
},
"laterality" : {
"system" : "http://snomed.info/sct",
"version" : "http://snomed.info/sct/900000000000207008/version/20260701",
"code" : "7771000",
"display" : "Left"
},
"started" : "2024-07-19T12:03:30+02:00",
"performer" : [
{
"actor" : {
🔗 "reference" : "Device/mii-exa-bildgebung-geraet"
}
}
],
"instance" : [
{
"extension" : [
{
"extension" : [
{
"url" : "pixelSpacingX",
"valueQuantity" : {
"value" : 1.36,
"unit" : "millimeter"
}
},
{
"url" : "pixelSpacingY",
"valueQuantity" : {
"value" : 1.36,
"unit" : "millimeter"
}
},
{
"url" : "sliceThickness",
"valueQuantity" : {
"value" : 4,
"unit" : "millimeter"
}
},
{
"url" : "imageType",
"valueCodeableConcept" : {
"coding" : [
{
"system" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-instance-image-type",
"code" : "DERIVED"
},
{
"system" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-instance-image-type",
"code" : "PRIMARY"
},
{
"system" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-instance-image-type",
"code" : "AXIAL"
}
]
}
}
],
"url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/StructureDefinition/mii-ex-bildgebung-instanz-details"
}
],
"uid" : "instance-example-uid",
"sopClass" : {
"system" : "urn:ietf:rfc:3986",
"code" : "urn:oid:1.2.840.10008.5.1.4.1.1.2"
},
"number" : 31
}
]
}
]
}