This page is part of the MII Implementation Guide Lungenfunktion (Pulmonary Function) (v2027.0.0-ballot.1: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
{
"resourceType" : "DiagnosticReport",
"id" : "mii-exa-lungenfunktion-bodyplethysmographie-befund",
"meta" : {
"profile" : [
🔗 "https://www.medizininformatik-initiative.de/fhir/ext/modul-lungenfunktion/StructureDefinition/mii-pr-lungenfunktion-bodyplethysmographie"
]
},
"language" : "en",
"text" : {
"status" : "generated",
"div" : "<div xml:lang=\"en\" lang=\"en\"><hr/><p><b>English</b></p><hr/><p class=\"res-header-id\"><b>Generated Narrative: DiagnosticReport mii-exa-lungenfunktion-bodyplethysmographie-befund</b></p><a name=\"mii-exa-lungenfunktion-bodyplethysmographie-befund\"> </a><a name=\"hcmii-exa-lungenfunktion-bodyplethysmographie-befund\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-mii-pr-lungenfunktion-bodyplethysmographie.html\">MII PR Lungenfunktion Bodyplethysmographie</a></p></div><h2><span title=\"Codes:{http://snomed.info/sct 28275007}\">Total body plethysmography (procedure)</span> (<span title=\"Codes:{http://snomed.info/sct 720449003}\">Pulmonary function report (record artifact)</span>) </h2><table class=\"grid\"><tr><td>Subject</td><td>Erika Beispielpatientin Female, DoB: 1970-01-01</td></tr><tr><td>Relevant Time</td><td>2024-07-19 12:03:30+0200</td></tr><tr><td>Reported</td><td>2024-07-19 13:03:20+0200</td></tr></table><p><b>Report Details</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>Value</b></td><td><b>Reference Range</b></td><td><b>Flags</b></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-fev1.html\"><span title=\"Codes:{http://snomed.info/sct 59328004}\">Forced expired volume in 1 second (observable entity)</span></a></td><td>2.23 L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL = 'L')</span></td><td>>2.98 L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL = 'L')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-fvc.html\"><span title=\"Codes:{http://snomed.info/sct 50834005}\">Forced vital capacity (observable entity)</span></a></td><td>2.65 L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL = 'L')</span></td><td>>3.76 L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL = 'L')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-fev1-fvc.html\"><span title=\"Codes:{http://snomed.info/sct 251944000}\">Forced expired volume in one second/forced vital capacity ratio (observable entity)</span></a></td><td>83.93 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code% = '%')</span></td><td>>68.88 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code% = '%')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-mef25.html\"><span title=\"Codes:{http://snomed.info/sct 251919008}\">Maximum expiratory flow rate at 25 percent of vital capacity (observable entity)</span></a></td><td>1.21 L/s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL/s = 'L/s')</span></td><td>>0.57 L/s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL/s = 'L/s')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-mef50.html\"><span title=\"Codes:{http://snomed.info/sct 251920002}\">Maximum expiratory flow rate at 50 percent of vital capacity (observable entity)</span></a></td><td>2.81 L/s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL/s = 'L/s')</span></td><td>>2.59 L/s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL/s = 'L/s')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-mef75.html\"><span title=\"Codes:{http://snomed.info/sct 251921003}\">Maximum expiratory flow rate at 75 percent of vital capacity (observable entity)</span></a></td><td>3.74 L/s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL/s = 'L/s')</span></td><td>>4.83 L/s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL/s = 'L/s')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-frc.html\"><span title=\"Codes:{http://loinc.org 19843-2}\">Functional residual capacity</span></a></td><td>3.48 L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL = 'L')</span></td><td>>2.43 L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL = 'L')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td colspan=\"4\"><i>Observation</i></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-tlc.html\"><span title=\"Codes:{http://snomed.info/sct 57566009}\">Total lung capacity (observable entity)</span></a></td><td>5 L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL = 'L')</span></td><td>>5.67 L<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL = 'L')</span></td><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td colspan=\"4\"><i>Observation</i></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-r.html\"><span title=\"Codes:{http://loinc.org 75946-4}\">Airway resistance</span></a></td><td>0.45 kPa/(L/s)<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codekPa/(L/s) = 'kPa/(L/s)')</span></td><td/><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-sg-total.html\"><span title=\"Codes:{http://snomed.info/sct 79412009}\">Specific airway conductance (observable entity)</span></a></td><td>0.92 /kPA.s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code/kPA.s = '/kPA.s')</span></td><td/><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-sr-eff.html\"><span title=\"Codes:{http://loinc.org 75946-4}\">Airway resistance</span></a></td><td>1.08 kPa.s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codekPa.s = 'kPa.s')</span></td><td/><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr><tr><td><a href=\"Observation-mii-exa-lungenfunktion-sr-total.html\"><span title=\"Codes:{http://loinc.org 75946-4}\">Airway resistance</span></a></td><td>0.45 kPa.s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codekPa.s = 'kPa.s')</span></td><td/><td>Final, <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></td></tr></table><p>Increased lung compliance</p><p><b>Coded Conclusions:</b></p><ul><li><span title=\"Codes:{http://snomed.info/sct 21368004}\">Increased lung compliance (finding)</span></li></ul></div>"
},
"status" : "final",
"category" : [
{
"coding" : [
{
"system" : "http://snomed.info/sct",
"version" : "http://snomed.info/sct/900000000000207008/version/20260701",
"code" : "720449003",
"display" : "Pulmonary function report (record artifact)"
}
]
}
],
"code" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"version" : "http://snomed.info/sct/900000000000207008/version/20260701",
"code" : "28275007",
"display" : "Total body plethysmography (procedure)"
}
]
},
"subject" : {
🔗 "reference" : "Patient/mii-exa-lungenfunktion-patient"
},
"encounter" : {
🔗 "reference" : "Encounter/mii-exa-lungenfunktion-kontakt"
},
"effectiveDateTime" : "2024-07-19T12:03:30+02:00",
"issued" : "2024-07-19T13:03:20+02:00",
"result" : [
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-fev1"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-fvc"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-fev1-fvc"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-mef25"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-mef50"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-mef75"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-frc"
},
{
"reference" : "Observation/mii-exa-lungenfunktion-rvl"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-tlc"
},
{
"reference" : "Observation/mii-exa-lungenfunktion-rvl-tlc"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-r"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-sg-total"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-sr-eff"
},
{
🔗 "reference" : "Observation/mii-exa-lungenfunktion-sr-total"
}
],
"conclusion" : "Increased lung compliance",
"conclusionCode" : [
{
"coding" : [
{
"system" : "http://snomed.info/sct",
"version" : "http://snomed.info/sct/900000000000207008/version/20260701",
"code" : "21368004",
"display" : "Increased lung compliance (finding)"
}
]
}
]
}