Dieses ValueSet enthält Codes für die im Kontext einer Beatmung verwendeten Parameter.
References
urn:iso:std:iso:11073:10101 version Not Stated (use latest from terminology server)| Code | Display |
| 150656 | Oxygenation Ratio |
| 151586 | Ventilation rate |
| 152498 | Unassisted spontaneous breath rate; respiration rate |
| 152490 | Total respiratory rate; total breath rate |
| 16929632 | Inspiratory time setting |
| 151832 | Ratio inspiration expiration time |
| 16929196 | Tidal volume setting |
| 151980 | Ventilation tidal volume |
| 152004 | Ventilation inspiratory minute volume |
| 16929860 | High pressure hold time setting Ventilator |
| 16929864 | Low pressure hold time setting Ventilator |
| 151948 | Ventilation inspiratory flow |
| 151944 | Ventilation expiratory flow |
| 153132 | Expired oxygen concentration (or partial pressure) in airway gas |
| 151975 | Mean pressure Respiratory system airway --on ventilator |
| 151973 | Pressure.max Respiratory system airway --on ventilator |
| 151692 | Thoracic compliance |
| 151976 | Applied PEEP |
| 152720 | Inspiratory airway pressure relative to PEEP or BAP |
| 151708 | End tidal carbon dioxide concentration (or partial pressure) in airway gas |