MII IG ICU
2027.0.0-ballot.3 -
Germany
This page is part of the MII IG ICU (v2027.0.0-ballot.3: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
<Observation xmlns="http://hl7.org/fhir">
<id value="mii-exa-icu-vent-positiv-endexspiratorischer-druck-eingestellt"/>
<meta>
<profile
value="https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-positiv-endexpiratorischer-druck"/>
</meta>
<language value="en"/>
<text>
<status value="generated"/>
<div xml:lang="en" lang="en"><hr/><p><b>English</b></p><hr/><p class="res-header-id"><b>Generated Narrative: Observation mii-exa-icu-vent-positiv-endexspiratorischer-druck-eingestellt</b></p><a name="mii-exa-icu-vent-positiv-endexspiratorischer-druck-eingestellt"> </a><a name="hcmii-exa-icu-vent-positiv-endexspiratorischer-druck-eingestellt"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-mii-pr-icu-vent-positiv-endexpiratorischer-druck.html">MII PR ICU Positiv Endexpiratorischer Druck</a></p></div><p><b>partOf</b>: <a href="Procedure-mii-exa-icu-vent-beatmung.html">Procedure Positive pressure airway ventilation (regime/therapy)</a></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://snomed.info/sct 40617009}">Artificial ventilation (regime/therapy)</span></p><p><b>code</b>: <span title="Codes:{http://loinc.org 76248-4}, {http://snomed.info/sct 250854009}, {urn:iso:std:iso:11073:10101 151976}">PEEP Respiratory system --on ventilator</span></p><p><b>subject</b>: <a href="Patient-mii-exa-icu-patient.html">Ida Intensivbeispiel (official) Female, DoB: 1998-06-15 ( Medical record number)</a></p><p><b>effective</b>: 2019-12-23 09:30:10+0100 --> 2019-12-23 10:30:10+0100</p><p><b>value</b>: 10.0 cm[H2O]<span style="background: LightGoldenRodYellow"> (Details: UCUM codecm[H2O] = 'cm[H2O]')</span></p><p><b>device</b>: <a href="DeviceMetric-mii-exa-icu-vent-eingestellte-parameter-beatmung.html">DeviceMetric: type = Artificial ventilation (regime/therapy); category = setting</a></p></div>
</text>
<partOf>🔗
<reference value="Procedure/mii-exa-icu-vent-beatmung"/>
</partOf>
<status value="final"/>
<category>
<coding>
<system value="http://snomed.info/sct"/>
<version
value="http://snomed.info/sct/900000000000207008/version/20260701"/>
<code value="40617009"/>
<display value="Artificial ventilation (regime/therapy)"/>
</coding>
</category>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="76248-4"/>
<display value="PEEP Respiratory system --on ventilator"/>
</coding>
<coding>
<system value="http://snomed.info/sct"/>
<version
value="http://snomed.info/sct/900000000000207008/version/20260701"/>
<code value="250854009"/>
<display value="Positive end expiratory pressure (observable entity)"/>
</coding>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="151976"/>
<display
value="Positive end expiratory pressure applied to the airway."/>
</coding>
</code>
<subject>🔗
<reference value="Patient/mii-exa-icu-patient"/>
</subject>
<effectivePeriod>
<start value="2019-12-23T09:30:10+01:00"/>
<end value="2019-12-23T10:30:10+01:00"/>
</effectivePeriod>
<valueQuantity>
<value value="10.0"/>
<unit value="cm[H2O]"/>
<system value="http://unitsofmeasure.org"/>
<code value="cm[H2O]"/>
</valueQuantity>
<device>🔗
<reference
value="DeviceMetric/mii-exa-icu-vent-eingestellte-parameter-beatmung"/>
</device>
</Observation>