Validation Results for MII_IG_Labor

Generated Mon Sep 14 07:21:19 UTC 2026, FHIR version 4.0.1 for de.medizininformatikinitiative.kerndatensatz.laborbefund#2027.0.0-ballot (canonical = https://www.medizininformatik-initiative.de/fhir/core/modul-labor (history)). See Full QA Report & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.3.2 which is a development version. The latest official release version isv2.3.4 Download Latest
Publication Code:n/a . PackageId = de.medizininformatikinitiative.kerndatensatz.laborbefund, Canonical = https://www.medizininformatik-initiative.de/fhir/core/modul-labor
Realm Check for n/a:
  • n/a
Language Info:Stated Languages: n/a. IG Resource Lang: en. 1 of 28 (3%) of resources have a language. Population Policy: NONE
Publication Request:
  • Error fetching package-list from https://www.medizininformatik-initiative.de/fhir/core/modul-labor: Error parsing JSON source: Unexpected content '<' in json format at Line 3 (path=[null])
  • No publication request found
Supressed Messages:10 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. de.medizininformatikinitiative.kerndatensatz.laborbefund2027.0.0-ballotR4https://www.medizininformatik-initiative.de/fhir/core/modul-labor
... hl7.fhir.uv.ips2.0.1 MR4http://hl7.org/fhir/uv/ipsfile:///web/publishing/work/task-89/draft/output
.... hl7.terminology.r47.2.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.2.0Latest Release is 7.3.0
..... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0
...... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0Latest Release is 7.3.0
....... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0Latest Release is 5.3.0
.... hl7.fhir.uv.ipa1.1.0 MR4http://hl7.org/fhir/uv/ipahttp://hl7.org/fhir/uv/ipa/STU1.1
..... hl7.terminology.r46.2.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.2.0Latest Release is 7.3.0
..... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
..... hl7.fhir.uv.smart-app-launch2.0.0 OR4http://hl7.org/fhir/smart-app-launchhttp://hl7.org/fhir/smart-app-launch/STU2Latest Release is 2.2.0
.... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0 (as above)
... de.medizininformatikinitiative.kerndatensatz.meta2027.0.0-ballot UR4https://www.medizininformatik-initiative.de/fhir/modul-metahttps://medizininformatik-initiative.github.io/kerndatensatz-meta/2027.0.0-ballot
.... hl7.fhir.uv.crmi2.0.0 MR4http://hl7.org/fhir/uv/crmihttp://hl7.org/fhir/uv/crmi/STU2
..... hl7.terminology.r47.2.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.2.0 (as above). Latest Release is 7.3.0
..... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0 (as above)
.... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0 (as above). Latest Release is 7.3.0
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above). Latest Release is 5.3.0
... hl7.fhir.uv.crmi2.0.0 MR4http://hl7.org/fhir/uv/crmihttp://hl7.org/fhir/uv/crmi/STU2 (as above)
... hl7.terminology.r47.1.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0 (as above). Latest Release is 7.3.0
... hl7.fhir.uv.tools.r41.1.2 MR4http://hl7.org/fhir/toolshttp://hl7.org/fhir/tools/1.1.2Internal Dependency
Templates: de.medizininformatikinitiative.template#1.3.4 -> fhir2.base.template#0.1.0
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):http://127.0.0.1:8090/fhir (details)
HTA Analysis:Non-HL7 Igs are exempt from terminology dependency analysis
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:
Previous Version Comparison: Unable to compare with previous version: Unable to find version history at https://www.medizininformatik-initiative.de/fhir/core/modul-labor (Problem #1 with package-list.json at https://www.medizininformatik-initiative.de/fhir/core/modul-labor: Error parsing JSON source: Unexpected content '<' in json format at Line 3 (path=[null]))
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 37, warn = 40, info = 71, broken links = 0, pinned = 672 (all) (in manifest Parameters/mii-param-labor-manifest).
FilenameErrorsWarningsHints
Build Errors040
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/CapabilityStatement-mii-cps-labor-capabilitystatement013
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ImplementationGuide-mii-ig-labor035
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/Observation-mii-exa-labor-laborwert033
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/Observation-mii-exa-labor-laborwert-data-absent-reason013
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/Observation-mii-exa-labor-laborwert-range022
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/Observation-mii-exa-labor-laborwert-ratio012
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ServiceRequest-mii-exa-labor-laboranforderung010
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/StructureDefinition-mii-ex-labor-interpretationsbeeinflussende-eigenschaft013
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/StructureDefinition-mii-ex-labor-quelle-klinisches-bezugsdatum013
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/StructureDefinition-mii-lm-labor013
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/StructureDefinition-mii-pr-labor-laboranforderung014
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/StructureDefinition-mii-pr-labor-laborbefund014
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/StructureDefinition-mii-pr-labor-laboruntersuchung015
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-identifier-type-codes022
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-interpretation0212
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-interpretation-eigenschaften-snomedct322
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich1822
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ823
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-codiert022
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ722
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-order-codes023
/home/runner/work/kerndatensatzmodul-labor/kerndatensatzmodul-labor/fsh-generated/resources/ValueSet-mii-vs-labor-quelle-klinisches-bezugsdatum122

n/a Show Validation Information

ImplementationGuide.idwarningThe Implementation Guide Resource id should be de.medizininformatikinitiative.kerndatensatz.laborbefund
output/de/extensions.htmlwarningThe html source has duplicate anchor Ids: Extension,Extension.extension,Extension.url,Extension.value_x_,Extension.value_x_.code,Extension.value_x_.system,end-xhtml,s-Extension,s-Extension.extension,s-Extension.id,s-Extension.url,s-Extension.value_x_,s-Extension.value_x_.code,s-Extension.value_x_.display,s-Extension.value_x_.extension,s-Extension.value_x_.id,s-Extension.value_x_.system,s-Extension.value_x_.userSelected,s-Extension.value_x_.version
output/en/extensions.htmlwarningThe html source has duplicate anchor Ids: Extension,Extension.extension,Extension.url,Extension.value_x_,Extension.value_x_.code,Extension.value_x_.system,end-xhtml,s-Extension,s-Extension.extension,s-Extension.id,s-Extension.url,s-Extension.value_x_,s-Extension.value_x_.code,s-Extension.value_x_.display,s-Extension.value_x_.extension,s-Extension.value_x_.id,s-Extension.value_x_.system,s-Extension.value_x_.userSelected,s-Extension.value_x_.version
5warningAn HTML fragment from the set [expansion-params.xhtml, expansion-params.xhtml] is not included anywhere in the produced implementation guide

fsh-generated/resources/CapabilityStatement-mii-cps-labor-capabilitystatement.json Show Validation Information (4)

PathSeverityMessageValidating
CapabilityStatement​.extension[9]​.value​.ofType(CodeableConcept) (l1​/c35438)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable CapabilityStatement
CapabilityStatement​.extension[10]​.value​.ofType(CodeableConcept) (l1​/c35619)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable CapabilityStatement
CapabilityStatement​.jurisdiction[0]​.coding[0]​.system (l1​/c37685)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) CRMI Shareable CapabilityStatement
ResourceinformationThe resource CapabilityStatement/mii-cps-labor-capabilitystatement could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ImplementationGuide-mii-ig-labor.json Show Validation Information (4)

PathSeverityMessageValidating
ImplementationGuide.language (l1/c340)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) ImplementationGuide
ImplementationGuide.language (l1/c340)informationReference to trial-use ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) ImplementationGuide
ImplementationGuide​.extension[17]​.value​.ofType(CodeableConcept) (l1​/c5930)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) ImplementationGuide
ImplementationGuide​.extension[18]​.value​.ofType(CodeableConcept) (l1​/c6111)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) ImplementationGuide
ImplementationGuide​.jurisdiction[0]​.coding[0]​.system (l1​/c6705)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) ImplementationGuide
ImplementationGuide​.dependsOn[3] (l1​/c7554)warningThe ImplementationGuide uses package hl7.fhir.uv.extensions.r4#5.2.0 released on 2025-02-10, but the most recent appropriate version is 5.3.0. This reference is getting old and the more recent version should be considered IG_DEPENDENCY_VERSION_WARNING_OLD--
ImplementationGuide​.dependsOn[4] (l1​/c7704)warningThe ImplementationGuide uses package hl7.terminology.r4#7.1.0 released on 2026-03-08, but the most recent appropriate version is 7.3.0. This reference is getting old and the more recent version should be considered IG_DEPENDENCY_VERSION_WARNING_OLD--
ResourceinformationThe resource ImplementationGuide/mii-ig-labor could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/Observation-mii-exa-labor-laborwert.json Show Validation Information (2)

PathSeverityMessageValidating
Observation.category[0] (l17/c6)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/observation-category|4.0.1 (from http://127.0.0.1:8090/fhir, see log) MII PR Labor Laboruntersuchung
Observation​.category[1]​.coding[0]​.system (l32​/c6)warningA definition for CodeSystem 'http://example.org/fhir/sid/Laborgruppe' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir) MII PR Labor Laboruntersuchung
Observation.category[1] (l32/c6)informationNone of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://example.org/fhir/sid/Laborgruppe#Niere/Elektrolyte) Terminology_TX_NoValid_3_CCMII PR Labor Laboruntersuchung
Observation.code.coding[0] (l100/c8)informationReference to trial-use ValueSet http://hl7.org/fhir/uv/ips/ValueSet/results-laboratory-pathology-observations-uv-ips|2.0.1 (from http://127.0.0.1:8090/fhir, see log) MII PR Labor Laboruntersuchung
Observation​.value​.ofType(Quantity) (l72​/c4)warningResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#umol/L') Terminology_PassThrough_TX_MessageMII PR Labor Laboruntersuchung
Observation​.value​.ofType(Quantity)​.extension[0]​.value​.ofType(Quantity) (l77​/c10)warningResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#mg/dL') Terminology_PassThrough_TX_MessageMII PR Labor Laboruntersuchung

fsh-generated/resources/Observation-mii-exa-labor-laborwert-data-absent-reason.json Show Validation Information (2)

PathSeverityMessageValidating
Observation.category[0] (l17/c6)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/observation-category|4.0.1 (from http://127.0.0.1:8090/fhir, see log) MII PR Labor Laboruntersuchung
Observation​.category[1]​.coding[0]​.system (l32​/c6)warningA definition for CodeSystem 'http://example.org/fhir/sid/Laborgruppe' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir) MII PR Labor Laboruntersuchung
Observation.category[1] (l32/c6)informationNone of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://example.org/fhir/sid/Laborgruppe#Niere/Elektrolyte) Terminology_TX_NoValid_3_CCMII PR Labor Laboruntersuchung
Observation.code.coding[0] (l64/c8)informationReference to trial-use ValueSet http://hl7.org/fhir/uv/ips/ValueSet/results-laboratory-pathology-observations-uv-ips|2.0.1 (from http://127.0.0.1:8090/fhir, see log) MII PR Labor Laboruntersuchung

fsh-generated/resources/Observation-mii-exa-labor-laborwert-range.json Show Validation Information (1)

PathSeverityMessageValidating
Observation.category[0] (l10/c6)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/observation-category|4.0.1 (from http://127.0.0.1:8090/fhir, see log) MII PR Labor Laboruntersuchung
Observation.code.coding[0] (l49/c8)informationReference to trial-use ValueSet http://hl7.org/fhir/uv/ips/ValueSet/results-laboratory-pathology-observations-uv-ips|2.0.1 (from http://127.0.0.1:8090/fhir, see log) MII PR Labor Laboruntersuchung
Observation​.value​.ofType(Range)​.low (l86​/c6)warningResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#/[HPF]') Terminology_PassThrough_TX_MessageMII PR Labor Laboruntersuchung
Observation​.value​.ofType(Range)​.high (l92​/c6)warningResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#/[HPF]') Terminology_PassThrough_TX_MessageMII PR Labor Laboruntersuchung

fsh-generated/resources/Observation-mii-exa-labor-laborwert-ratio.json Show Validation Information (1)

PathSeverityMessageValidating
Observation.category[0] (l10/c6)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/observation-category|4.0.1 (from http://127.0.0.1:8090/fhir, see log) MII PR Labor Laboruntersuchung
Observation.code.coding[0] (l55/c8)informationReference to trial-use ValueSet http://hl7.org/fhir/uv/ips/ValueSet/results-laboratory-pathology-observations-uv-ips|2.0.1 (from http://127.0.0.1:8090/fhir, see log) MII PR Labor Laboruntersuchung
Observation​.value​.ofType(Quantity) (l46​/c4)warningResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#mg/(24.h)') Terminology_PassThrough_TX_MessageMII PR Labor Laboruntersuchung

fsh-generated/resources/ServiceRequest-mii-exa-labor-laboranforderung.json Show Validation Information (2)

PathSeverityMessageValidating
ServiceRequest​.code​.coding[0]​.system (l48​/c4)warningA definition for CodeSystem 'http://example.org/fhir/CodeSystem/LabTests' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir) MII PR Labor Laboranforderung

fsh-generated/resources/StructureDefinition-mii-ex-labor-interpretationsbeeinflussende-eigenschaft.json Show Validation Information (4)

PathSeverityMessageValidating
StructureDefinition​.extension[9]​.value​.ofType(CodeableConcept) (l1​/c37828)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.extension[10]​.value​.ofType(CodeableConcept) (l1​/c38009)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.jurisdiction[0]​.coding[0]​.system (l1​/c40046)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) CRMI Shareable StructureDefinition
ResourceinformationThe resource StructureDefinition/mii-ex-labor-interpretationsbeeinflussende-eigenschaft could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-mii-ex-labor-quelle-klinisches-bezugsdatum.json Show Validation Information (4)

PathSeverityMessageValidating
StructureDefinition​.extension[9]​.value​.ofType(CodeableConcept) (l1​/c36590)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.extension[10]​.value​.ofType(CodeableConcept) (l1​/c36771)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.jurisdiction[0]​.coding[0]​.system (l1​/c38727)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) CRMI Shareable StructureDefinition
ResourceinformationThe resource StructureDefinition/mii-ex-labor-quelle-klinisches-bezugsdatum could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-mii-lm-labor.json Show Validation Information (4)

PathSeverityMessageValidating
StructureDefinition​.extension[9]​.value​.ofType(CodeableConcept) (l1​/c228213)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.extension[10]​.value​.ofType(CodeableConcept) (l1​/c228394)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.jurisdiction[0]​.coding[0]​.system (l1​/c230298)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) CRMI Shareable StructureDefinition
ResourceinformationThe resource StructureDefinition/mii-lm-labor could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-mii-pr-labor-laboranforderung.json Show Validation Information (4)

PathSeverityMessageValidating
StructureDefinition​.extension[9]​.value​.ofType(CodeableConcept) (l1​/c214644)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.extension[10]​.value​.ofType(CodeableConcept) (l1​/c214825)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.jurisdiction[0]​.coding[0]​.system (l1​/c217527)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) CRMI Shareable StructureDefinition
StructureDefinition​.snapshot​.element[12]​.binding​.extension[0] (l1​/c235396)informationThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead' MSG_DEPENDS_ON_DEPRECATED_NOTECRMI Shareable StructureDefinition
ResourceinformationThe resource StructureDefinition/mii-pr-labor-laboranforderung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-mii-pr-labor-laborbefund.json Show Validation Information (4)

PathSeverityMessageValidating
StructureDefinition​.extension[9]​.value​.ofType(CodeableConcept) (l1​/c253140)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.extension[10]​.value​.ofType(CodeableConcept) (l1​/c253321)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.jurisdiction[0]​.coding[0]​.system (l1​/c256072)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) CRMI Shareable StructureDefinition
StructureDefinition​.snapshot​.element[87]​.type[0]​.extension[1] (l1​/c385289)informationThe extension http://hl7.org/fhir/StructureDefinition/regex|5.3.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex' MSG_DEPENDS_ON_DEPRECATED_NOTECRMI Shareable StructureDefinition
ResourceinformationThe resource StructureDefinition/mii-pr-labor-laborbefund could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/StructureDefinition-mii-pr-labor-laboruntersuchung.json Show Validation Information (4)

PathSeverityMessageValidating
StructureDefinition​.text​.div (l1​/c424018)informationHyperlink scheme 'file' in 'file:///web/publishing/work/task-89/draft/output/ValueSet-results-laboratory-pathology-observations-uv-ips.html' at 'div/div/table/tr/td/a' for 'Results Laboratory/Pathology Observation - IPS' is not a widely supported protocol and should be checked TYPE_SPECIFIC_CHECKS_DT_XHTML_UNKNOWN_HREFCRMI Shareable StructureDefinition
StructureDefinition​.extension[9]​.value​.ofType(CodeableConcept) (l1​/c426003)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.extension[10]​.value​.ofType(CodeableConcept) (l1​/c426184)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) CRMI Shareable StructureDefinition
StructureDefinition​.jurisdiction[0]​.coding[0]​.system (l1​/c428880)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) CRMI Shareable StructureDefinition
StructureDefinition​.snapshot​.element[78]​.pattern​.ofType(Coding)informationThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users) SD_VALUE_TYPE_REPEAT_HINT--
ResourceinformationThe resource StructureDefinition/mii-pr-labor-laboruntersuchung could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-mii-vs-labor-identifier-type-codes.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c5662)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c5843)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c7837)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ResourcewarningThe resource ValueSet/mii-vs-labor-identifier-type-codes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-mii-vs-labor-interpretation.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c8815)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c8996)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c10995)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[0]​.designation[0]​.language (l1​/c11189)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[0]​.designation[0]​.language (l1​/c11189)informationReference to trial-use ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[1]​.designation[0]​.language (l1​/c11291)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[1]​.designation[0]​.language (l1​/c11291)informationReference to trial-use ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[2]​.designation[0]​.language (l1​/c11390)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[2]​.designation[0]​.language (l1​/c11390)informationReference to trial-use ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[3]​.designation[0]​.language (l1​/c11474)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[3]​.designation[0]​.language (l1​/c11474)informationReference to trial-use ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[4]​.designation[0]​.language (l1​/c11573)informationReference to draft ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[4]​.designation[0]​.language (l1​/c11573)informationReference to trial-use ValueSet http://hl7.org/fhir/ValueSet/languages|4.0.1 (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ResourcewarningThe resource ValueSet/mii-vs-labor-interpretation should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-mii-vs-labor-interpretation-eigenschaften-snomedct.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c5765)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c5946)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c8028)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[1] (l1​/c8270)errorThe code '118127007' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (118127007) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[2] (l1​/c8320)errorThe code '118129005' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (118129005) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[3] (l1​/c8382)errorThe code '167569004' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (167569004) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ResourcewarningThe resource ValueSet/mii-vs-labor-interpretation-eigenschaften-snomedct should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c9663)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c9844)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c11787)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[1] (l1​/c11980)errorThe code '18718-7' is not valid in the system http://loinc.org version 2.82 (18718-7) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[2] (l1​/c12035)errorThe code '18719-5' is not valid in the system http://loinc.org version 2.82 (18719-5) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[3] (l1​/c12092)errorThe code '18720-3' is not valid in the system http://loinc.org version 2.82 (18720-3) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[4] (l1​/c12165)errorThe code '18721-1' is not valid in the system http://loinc.org version 2.82 (18721-1) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[5] (l1​/c12220)errorThe code '18722-9' is not valid in the system http://loinc.org version 2.82 (18722-9) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[6] (l1​/c12276)errorThe code '18723-7' is not valid in the system http://loinc.org version 2.82 (18723-7) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[7] (l1​/c12325)errorThe code '18724-5' is not valid in the system http://loinc.org version 2.82 (18724-5) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[8] (l1​/c12383)errorThe code '18725-2' is not valid in the system http://loinc.org version 2.82 (18725-2) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[9] (l1​/c12437)errorThe code '18727-8' is not valid in the system http://loinc.org version 2.82 (18727-8) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[10] (l1​/c12493)errorThe code '18728-6' is not valid in the system http://loinc.org version 2.82 (18728-6) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[11] (l1​/c12549)errorThe code '18729-4' is not valid in the system http://loinc.org version 2.82 (18729-4) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[12] (l1​/c12604)errorThe code '18767-4' is not valid in the system http://loinc.org version 2.82 (18767-4) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[13] (l1​/c12674)errorThe code '18768-2' is not valid in the system http://loinc.org version 2.82 (18768-2) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[14] (l1​/c12740)errorThe code '18769-0' is not valid in the system http://loinc.org version 2.82 (18769-0) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[15] (l1​/c12805)errorThe code '26435-8' is not valid in the system http://loinc.org version 2.82 (26435-8) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[16] (l1​/c12861)errorThe code '26436-6' is not valid in the system http://loinc.org version 2.82 (26436-6) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[17] (l1​/c12926)errorThe code '26437-4' is not valid in the system http://loinc.org version 2.82 (26437-4) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[18] (l1​/c12980)errorThe code '26438-2' is not valid in the system http://loinc.org version 2.82 (26438-2) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ResourcewarningThe resource ValueSet/mii-vs-labor-laborbereich should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c7051)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c7232)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c9177)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[1] (l1​/c9464)errorThe code '260348001' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260348001) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[2] (l1​/c9539)errorThe code '260349009' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260349009) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[3] (l1​/c9615)errorThe code '260350009' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260350009) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[4] (l1​/c9689)errorThe code '410594000' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (410594000) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[5] (l1​/c9746)errorThe code '260405006' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260405006) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[6] (l1​/c9814)errorThe code '441614007' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (441614007) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[7] (l1​/c9882)errorThe code '441517005' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (441517005) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[8] (l1​/c9952)errorThe code '441521003' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (441521003) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet.compose.include[0] (l1/c9954)informationThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Present + out of ++++ (qualifier value), Present ++ out of ++++ (qualifier value), Present +++ out of ++++ (qualifier value), Present ++++ out of ++++ (qualifier value), Definitely NOT present (qualifier value)] and examples for no FSN: [Present one plus out of three plus, Present two plus out of three plus, Present three plus out of three plus]) VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED--
ResourcewarningThe resource ValueSet/mii-vs-labor-laborergbenis-semiquantitativ should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-codiert.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c4763)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c4944)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c6895)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ResourcewarningThe resource ValueSet/mii-vs-labor-laborergebnis-codiert should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c7482)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c7663)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c9587)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[1] (l1​/c9858)errorThe code '280416009' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (280416009) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[2] (l1​/c9918)errorThe code '260385009' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260385009) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[3] (l1​/c9982)errorThe code '260415000' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260415000) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[4] (l1​/c10046)errorThe code '419984006' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (419984006) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[5] (l1​/c10106)errorThe code '260373001' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260373001) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[6] (l1​/c10164)errorThe code '52101004' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (52101004) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ValueSet​.compose​.include[0]​.concept[7] (l1​/c10238)errorThe code '410594000' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (410594000) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ResourcewarningThe resource ValueSet/mii-vs-labor-laborergebnis-qualitativ should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

fsh-generated/resources/ValueSet-mii-vs-labor-order-codes.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c4355)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c4536)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c6439)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ResourcewarningThe resource ValueSet/mii-vs-labor-order-codes should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --
ValueSet​.where(id = 'mii-vs-labor-order-codes')informationThe value set expansion is too large, and only a subset has been displayed --

fsh-generated/resources/ValueSet-mii-vs-labor-quelle-klinisches-bezugsdatum.json Show Validation Information (8)

PathSeverityMessageValidating
ValueSet​.extension[6]​.value​.ofType(CodeableConcept) (l1​/c5333)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.extension[7]​.value​.ofType(CodeableConcept) (l1​/c5514)informationReference to experimental CodeSystem http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl|25.6.0-e (from http://127.0.0.1:8090/fhir) Shareable ValueSet
ValueSet​.jurisdiction[0]​.coding[0]​.system (l1​/c7473)warningA definition for CodeSystem 'urn:iso:std:iso:3166:-2' could not be found, so the code cannot be validated (from http://127.0.0.1:8090/fhir, see log) Shareable ValueSet
ValueSet​.compose​.include[0]​.concept[1] (l1​/c7739)errorThe code '281271004' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (281271004) VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER--
ResourcewarningThe resource ValueSet/mii-vs-labor-quelle-klinisches-bezugsdatum should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root) --

Suppressed Messages (Warnings, hints, broken links)

Das CodeSystem gehoert der FHIR-Kernspezifikation und wird dort als draft gefuehrt.

Das Modul ist R4; dort ist type=pattern korrekt. Der Hinweis zielt auf R5.

Dasselbe fuer das HL7-shareablevalueset-Profil.

Die Elementnamen des Logical Models folgen dem abgenommenen ART-DECOR-Modell (deutsche CamelCase-Begriffe).

Die uri-Sub-Extension von package-source traegt die Modul-Basis-URL; die identifiziert bewusst kein Artefakt.

Dieselbe Entscheidung; quantity-precision liegt zusaetzlich in hl7.fhir.r4.core, die Mehrdeutigkeit ist dort strukturell.

Ein Beispiel ergaenzt an category.coding einen lokalen Laborgruppen-Code - offenes Slicing, so gewollt.

Extension-Referenzen bleiben unversioniert wie im ganzen KDS; die Version legt pin-canonicals bei der Publikation fest.

Folge der Mehrfach-Profilierung: jede Extension trifft einen Slice, nur in einem der drei deklarierten Profile.

Quittung fuer pin-canonicals: pin-all - der Publisher meldet jede Referenz, die er auf eine Version festlegt.

Errors sorted by type


IG_DEPENDENCY_VERSION_WARNING_OLD

fsh-generated/resources/ImplementationGuide-mii-ig-labor.jsonThe ImplementationGuide uses package hl7.fhir.uv.extensions.r4#5.2.0 released on 2025-02-10, but the most recent appropriate version is 5.3.0. This reference is getting old and the more recent version should be considered--
fsh-generated/resources/ImplementationGuide-mii-ig-labor.jsonThe ImplementationGuide uses package hl7.terminology.r4#7.1.0 released on 2026-03-08, but the most recent appropriate version is 7.3.0. This reference is getting old and the more recent version should be considered--

MSG_DEPENDS_ON_DEPRECATED_NOTE

fsh-generated/resources/StructureDefinition-mii-pr-labor-laboranforderung.jsonThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'CRMI Shareable StructureDefinition
fsh-generated/resources/StructureDefinition-mii-pr-labor-laborbefund.jsonThe extension http://hl7.org/fhir/StructureDefinition/regex|5.3.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex'CRMI Shareable StructureDefinition

SD_VALUE_TYPE_REPEAT_HINT

fsh-generated/resources/StructureDefinition-mii-pr-labor-laboruntersuchung.jsonThe repeating element has a pattern. The pattern will apply to all the repeats (this has not been clear to all users)--

TYPE_SPECIFIC_CHECKS_DT_XHTML_UNKNOWN_HREF

fsh-generated/resources/StructureDefinition-mii-pr-labor-laboruntersuchung.jsonHyperlink scheme 'file' in 'file:///web/publishing/work/task-89/draft/output/ValueSet-results-laboratory-pathology-observations-uv-ips.html' at 'div/div/table/tr/td/a' for 'Results Laboratory/Pathology Observation - IPS' is not a widely supported protocol and should be checkedCRMI Shareable StructureDefinition

Terminology_PassThrough_TX_Message

fsh-generated/resources/Observation-mii-exa-labor-laborwert.jsonResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#umol/L')MII PR Labor Laboruntersuchung
fsh-generated/resources/Observation-mii-exa-labor-laborwert.jsonResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#mg/dL')MII PR Labor Laboruntersuchung
fsh-generated/resources/Observation-mii-exa-labor-laborwert-range.jsonResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#/[HPF]')MII PR Labor Laboruntersuchung
fsh-generated/resources/Observation-mii-exa-labor-laborwert-range.jsonResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#/[HPF]')MII PR Labor Laboruntersuchung
fsh-generated/resources/Observation-mii-exa-labor-laborwert-ratio.jsonResolved system http://unitsofmeasure.org (v3.0.1), but the definition doesn't include any codes, so the code has not been validated (for 'http://unitsofmeasure.org#mg/(24.h)')MII PR Labor Laboruntersuchung

Terminology_TX_NoValid_3_CC

fsh-generated/resources/Observation-mii-exa-labor-laborwert.jsonNone of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://example.org/fhir/sid/Laborgruppe#Niere/Elektrolyte)MII PR Labor Laboruntersuchung
fsh-generated/resources/Observation-mii-exa-labor-laborwert-data-absent-reason.jsonNone of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.0.1), and a coding is recommended to come from this value set (codes = http://example.org/fhir/sid/Laborgruppe#Niere/Elektrolyte)MII PR Labor Laboruntersuchung

VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED

fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Present + out of ++++ (qualifier value), Present ++ out of ++++ (qualifier value), Present +++ out of ++++ (qualifier value), Present ++++ out of ++++ (qualifier value), Definitely NOT present (qualifier value)] and examples for no FSN: [Present one plus out of three plus, Present two plus out of three plus, Present three plus out of three plus])--

VALUESET_INCLUDE_INVALID_CONCEPT_CODE_VER

fsh-generated/resources/ValueSet-mii-vs-labor-interpretation-eigenschaften-snomedct.jsonThe code '118127007' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (118127007)--
fsh-generated/resources/ValueSet-mii-vs-labor-interpretation-eigenschaften-snomedct.jsonThe code '118129005' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (118129005)--
fsh-generated/resources/ValueSet-mii-vs-labor-interpretation-eigenschaften-snomedct.jsonThe code '167569004' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (167569004)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18718-7' is not valid in the system http://loinc.org version 2.82 (18718-7)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18719-5' is not valid in the system http://loinc.org version 2.82 (18719-5)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18720-3' is not valid in the system http://loinc.org version 2.82 (18720-3)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18721-1' is not valid in the system http://loinc.org version 2.82 (18721-1)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18722-9' is not valid in the system http://loinc.org version 2.82 (18722-9)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18723-7' is not valid in the system http://loinc.org version 2.82 (18723-7)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18724-5' is not valid in the system http://loinc.org version 2.82 (18724-5)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18725-2' is not valid in the system http://loinc.org version 2.82 (18725-2)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18727-8' is not valid in the system http://loinc.org version 2.82 (18727-8)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18728-6' is not valid in the system http://loinc.org version 2.82 (18728-6)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18729-4' is not valid in the system http://loinc.org version 2.82 (18729-4)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18767-4' is not valid in the system http://loinc.org version 2.82 (18767-4)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18768-2' is not valid in the system http://loinc.org version 2.82 (18768-2)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '18769-0' is not valid in the system http://loinc.org version 2.82 (18769-0)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '26435-8' is not valid in the system http://loinc.org version 2.82 (26435-8)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '26436-6' is not valid in the system http://loinc.org version 2.82 (26436-6)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '26437-4' is not valid in the system http://loinc.org version 2.82 (26437-4)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborbereich.jsonThe code '26438-2' is not valid in the system http://loinc.org version 2.82 (26438-2)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThe code '260348001' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260348001)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThe code '260349009' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260349009)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThe code '260350009' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260350009)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThe code '410594000' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (410594000)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThe code '260405006' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260405006)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThe code '441614007' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (441614007)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThe code '441517005' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (441517005)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergbenis-semiquantitativ.jsonThe code '441521003' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (441521003)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ.jsonThe code '280416009' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (280416009)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ.jsonThe code '260385009' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260385009)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ.jsonThe code '260415000' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260415000)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ.jsonThe code '419984006' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (419984006)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ.jsonThe code '260373001' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (260373001)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ.jsonThe code '52101004' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (52101004)--
fsh-generated/resources/ValueSet-mii-vs-labor-laborergebnis-qualitativ.jsonThe code '410594000' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (410594000)--
fsh-generated/resources/ValueSet-mii-vs-labor-quelle-klinisches-bezugsdatum.jsonThe code '281271004' is not valid in the system http://snomed.info/sct version http://snomed.info/sct/900000000000207008/version/20260701 (281271004)--