MII IG Kerndatensatz-Modul Bildgebung
2027.0.0-ballot.1 -
Germany
This page is part of the MII Implementation Guide Bildgebung (v2027.0.0-ballot.1: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
| Active Stand: 2026-09-15 |
<CodeSystem xmlns="http://hl7.org/fhir">
<id value="mii-cs-bildgebung-series-type"/>
<meta>
<profile
value="http://hl7.org/fhir/StructureDefinition/shareablecodesystem"/>
</meta>
<language value="de"/>
<text>
<status value="generated"/>
<div xml:lang="de" lang="de"><hr/><p><b>German</b></p><hr/><p class="res-header-id"><b>Generated Narrative: CodeSystem mii-cs-bildgebung-series-type</b></p><a name="de-mii-cs-bildgebung-series-type"> </a><a name="de-hcmii-cs-bildgebung-series-type"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/uv/crmi/STU2/StructureDefinition-shareablecodesystem.html">Shareable CodeSystem</a></p></div><p>This case-sensitive code system <code>https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-series-type</code> defines the following codes:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td style="white-space:nowrap">STATIC<a name="de-mii-cs-bildgebung-series-type-STATIC"> </a></td><td>a group of images at varying spatial locations at the same time</td></tr><tr><td style="white-space:nowrap">DYNAMIC<a name="de-mii-cs-bildgebung-series-type-DYNAMIC"> </a></td><td>a group of images at a set of spatial locations (e.g., slices) at varying time slices, with all spatial locations acquired at all time slices</td></tr><tr><td style="white-space:nowrap">GATED<a name="de-mii-cs-bildgebung-series-type-GATED"> </a></td><td>a group of images at the same spatial location, same starting and ending time, but acquired in different time slots of (possibly) different R-R intervals</td></tr><tr><td style="white-space:nowrap">WHOLEBODY<a name="de-mii-cs-bildgebung-series-type-WHOLEBODY"> </a></td><td>same as STATIC, except covering multiple transverse fields of view (and therefore acquired at a different time)</td></tr><tr><td style="white-space:nowrap">IMAGE<a name="de-mii-cs-bildgebung-series-type-IMAGE"> </a></td><td>a tomographic image slice</td></tr><tr><td style="white-space:nowrap">REPROJECTION<a name="de-mii-cs-bildgebung-series-type-REPROJECTION"> </a></td><td>a projection image derived from forward projection through slices of tomographic images, using the algorithm defined in Reprojection Method (0054,1004)</td></tr></table></div>
</text>
<extension
url="https://www.medizininformatik-initiative.de/fhir/modul-meta/StructureDefinition/mii-ex-meta-license-codeable">
<valueCodeableConcept>
<coding>
<system value="http://hl7.org/fhir/spdx-license"/>
<code value="CC-BY-4.0"/>
<display value="Creative Commons Attribution 4.0 International"/>
</coding>
</valueCodeableConcept>
</extension>
<url
value="https://www.medizininformatik-initiative.de/fhir/ext/modul-bildgebung/CodeSystem/mii-cs-bildgebung-series-type"/>
<version value="2027.0.0-ballot.1"/>
<name value="MII_CS_Bildgebung_Series_Type"/>
<title value="MII CS Bildgebung Series Type"/>
<status value="active"/>
<experimental value="false"/>
<date value="2026-09-15"/>
<publisher value="Medizininformatik Initiative"/>
<contact>
<name value="Medizininformatik Initiative"/>
<telecom>
<system value="url"/>
<value value="https://www.medizininformatik-initiative.de/"/>
</telecom>
</contact>
<description value="Series Type für PET Untersuchungen"/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="DE"/>
<display value="Germany"/>
</coding>
</jurisdiction>
<caseSensitive value="true"/>
<content value="complete"/>
<count value="6"/>
<concept>
<code value="STATIC"/>
<display
value="a group of images at varying spatial locations at the same time"/>
</concept>
<concept>
<code value="DYNAMIC"/>
<display
value="a group of images at a set of spatial locations (e.g., slices) at varying time slices, with all spatial locations acquired at all time slices"/>
</concept>
<concept>
<code value="GATED"/>
<display
value="a group of images at the same spatial location, same starting and ending time, but acquired in different time slots of (possibly) different R-R intervals"/>
</concept>
<concept>
<code value="WHOLEBODY"/>
<display
value="same as STATIC, except covering multiple transverse fields of view (and therefore acquired at a different time)"/>
</concept>
<concept>
<code value="IMAGE"/>
<display value="a tomographic image slice"/>
</concept>
<concept>
<code value="REPROJECTION"/>
<display
value="a projection image derived from forward projection through slices of tomographic images, using the algorithm defined in Reprojection Method (0054,1004)"/>
</concept>
</CodeSystem>