MII IG Laborbefund
2027.0.0-ballot - Germany

MII IG Laborbefund - Local Development build (v2027.0.0-ballot) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: MII VS Labor Laborergbenis Semiquantitativ

Active as of 2023-12-12

Raw json | Download

{
  "resourceType" : "ValueSet",
  "id" : "mii-vs-labor-laborergbenis-semiquantitativ",
  "meta" : {
    "extension" : [
      {
        "extension" : [
          {
            "url" : "packageId",
            "valueId" : "de.medizininformatikinitiative.kerndatensatz.laborbefund"
          },
          {
            "url" : "version",
            "valueString" : "2027.0.0-ballot"
          },
          {
            "url" : "uri",
            "valueUri" : "https://www.medizininformatik-initiative.de/fhir/core/modul-labor"
          }
        ],
        "url" : "http://hl7.org/fhir/StructureDefinition/package-source"
      }
    ],
    "profile" : [
      🔗 "http://hl7.org/fhir/StructureDefinition/shareablevalueset"🔗 ,
      "http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-shareablevalueset"🔗 ,
      "http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-publishablevalueset"🔗 ,
      "http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-computablevalueset"
    ]
  },
  "language" : "en",
  "text" : {
    "status" : "generated",
    "div" : "<div xml:lang=\"en\" lang=\"en\"><hr/><p><b>English</b></p><hr/><p class=\"res-header-id\"><b>Generated Narrative: ValueSet mii-vs-labor-laborergbenis-semiquantitativ</b></p><a name=\"mii-vs-labor-laborergbenis-semiquantitativ\"> </a><a name=\"hcmii-vs-labor-laborergbenis-semiquantitativ\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/><p style=\"margin-bottom: 0px\">Profiles: <a href=\"http://hl7.org/fhir/uv/crmi/STU2/StructureDefinition-shareablevalueset.html\">Shareable ValueSet</a>, <a href=\"http://hl7.org/fhir/uv/crmi/STU2/StructureDefinition-crmi-shareablevalueset.html\">CRMI Shareable ValueSet</a>, <a href=\"http://hl7.org/fhir/uv/crmi/STU2/StructureDefinition-crmi-publishablevalueset.html\">CRMI Publishable ValueSet</a>, <a href=\"http://hl7.org/fhir/uv/crmi/STU2/StructureDefinition-crmi-computablevalueset.html\">CRMI Computable ValueSet</a></p></div><ul><li>Include these codes as defined in <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a><span title=\"Version is explicitly stated to be http://snomed.info/sct/900000000000207008/version/20260701\"> version &#x1F4CD;http://snomed.info/sct/900000000000207008/version/20260701</span><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"http://snomed.info/id/260347006\">260347006</a></td><td>Present + out of ++++ (qualifier value)</td></tr><tr><td><a href=\"http://snomed.info/id/260348001\">260348001</a></td><td>Present ++ out of ++++ (qualifier value)</td></tr><tr><td><a href=\"http://snomed.info/id/260349009\">260349009</a></td><td>Present +++ out of ++++ (qualifier value)</td></tr><tr><td><a href=\"http://snomed.info/id/260350009\">260350009</a></td><td>Present ++++ out of ++++ (qualifier value)</td></tr><tr><td><a href=\"http://snomed.info/id/410594000\">410594000</a></td><td>Definitely NOT present (qualifier value)</td></tr><tr><td><a href=\"http://snomed.info/id/260405006\">260405006</a></td><td>Trace (qualifier value)</td></tr><tr><td><a href=\"http://snomed.info/id/441614007\">441614007</a></td><td>Present one plus out of three plus</td></tr><tr><td><a href=\"http://snomed.info/id/441517005\">441517005</a></td><td>Present two plus out of three plus</td></tr><tr><td><a href=\"http://snomed.info/id/441521003\">441521003</a></td><td>Present three plus out of three plus</td></tr></table></li></ul></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-versionAlgorithm",
      "valueCoding" : {
        "system" : "http://hl7.org/fhir/version-algorithm",
        "code" : "semver",
        "display" : "SemVer"
      }
    },
    {
      "url" : "https://www.medizininformatik-initiative.de/fhir/modul-meta/StructureDefinition/mii-ex-meta-license-codeable",
      "valueCodeableConcept" : {
        "coding" : [
          {
            "system" : "http://hl7.org/fhir/spdx-license",
            "code" : "CC-BY-4.0",
            "display" : "Creative Commons Attribution 4.0 International"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/cqf-knowledgeCapability",
      "valueCode" : "shareable"
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/cqf-knowledgeCapability",
      "valueCode" : "publishable"
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/cqf-knowledgeCapability",
      "valueCode" : "computable"
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-versionPolicy",
      "valueCodeableConcept" : {
        "coding" : [
          {
            "system" : "http://terminology.hl7.org/CodeSystem/artifact-version-policy-codes",
            "code" : "package",
            "display" : "Package"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-topic",
      "valueCodeableConcept" : {
        "coding" : [
          {
            "system" : "http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl",
            "code" : "C36292"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-topic",
      "valueCodeableConcept" : {
        "coding" : [
          {
            "system" : "http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl",
            "code" : "C25294"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-author",
      "valueContactDetail" : {
        "telecom" : [
          {
            "system" : "email",
            "value" : "pw@gefyra.de"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-editor",
      "valueContactDetail" : {
        "name" : "Taskforce Core Data Set"
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-reviewer",
      "valueContactDetail" : {
        "name" : "Interoperability Working Group",
        "telecom" : [
          {
            "system" : "url",
            "value" : "https://www.medizininformatik-initiative.de/en/collaboration/interoperability-working-group"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-reviewer",
      "valueContactDetail" : {
        "name" : "National Steering Committee",
        "telecom" : [
          {
            "system" : "url",
            "value" : "https://www.medizininformatik-initiative.de/en/collaboration/national-steering-committee"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-endorser",
      "valueContactDetail" : {
        "name" : "Interoperability Working Group",
        "telecom" : [
          {
            "system" : "url",
            "value" : "https://www.medizininformatik-initiative.de/en/collaboration/interoperability-working-group"
          }
        ]
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/artifact-endorser",
      "valueContactDetail" : {
        "name" : "National Steering Committee",
        "telecom" : [
          {
            "system" : "url",
            "value" : "https://www.medizininformatik-initiative.de/en/collaboration/national-steering-committee"
          }
        ]
      }
    }
  ],
  "url" : "https://www.medizininformatik-initiative.de/fhir/core/modul-labor/ValueSet/Laborergebnis-semiquantitativ",
  "version" : "2027.0.0-ballot",
  "name" : "MII_VS_Labor_Laborergbenis_Semiquantitativ",
  "title" : "MII VS Labor Laborergbenis Semiquantitativ",
  "status" : "active",
  "experimental" : false,
  "date" : "2023-12-12",
  "publisher" : "Medizininformatik Initiative",
  "contact" : [
    {
      "name" : "Medizininformatik Initiative",
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://www.medizininformatik-initiative.de"
        }
      ]
    }
  ],
  "description" : "Kodierung für semi-quantitative Laborergebnisse",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "urn:iso:std:iso:3166",
          "code" : "DE",
          "display" : "Germany"
        }
      ]
    }
  ],
  "compose" : {
    "include" : [
      {
        "system" : "http://snomed.info/sct",
        "version" : "http://snomed.info/sct/900000000000207008/version/20260701",
        "concept" : [
          {
            "code" : "260347006",
            "display" : "Present + out of ++++ (qualifier value)"
          },
          {
            "code" : "260348001",
            "display" : "Present ++ out of ++++ (qualifier value)"
          },
          {
            "code" : "260349009",
            "display" : "Present +++ out of ++++ (qualifier value)"
          },
          {
            "code" : "260350009",
            "display" : "Present ++++ out of ++++ (qualifier value)"
          },
          {
            "code" : "410594000",
            "display" : "Definitely NOT present (qualifier value)"
          },
          {
            "code" : "260405006",
            "display" : "Trace (qualifier value)"
          },
          {
            "code" : "441614007",
            "display" : "Present one plus out of three plus"
          },
          {
            "code" : "441517005",
            "display" : "Present two plus out of three plus"
          },
          {
            "code" : "441521003",
            "display" : "Present three plus out of three plus"
          }
        ]
      }
    ]
  }
}