MII IG Laborbefund
2027.0.0-ballot - Germany

MII IG Laborbefund - Local Development build (v2027.0.0-ballot) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Artifacts Summary

This page provides a list of the FHIR artifacts defined as part of this implementation guide.

Behavior: Capability Statements

The following artifacts define the specific capabilities that different types of systems are expected to have in order to comply with this implementation guide. Systems conforming to this implementation guide are expected to declare conformance to one or more of the following capability statements.

MII CPS Labor CapabilityStatement

Das vorliegende CapabilityStatement beschreibt alle verpflichtenden Interaktionen die ein konformes System unterstützen muss, um das Modul Labor der Medizininformatik Initiative zu implementieren.

Structures: Logical Models

These define data models that represent the domain covered by this implementation guide in more business-friendly terms than the underlying FHIR resources.

MII LM Labor

Logische Repräsentation des Basismoduls Labor

Structures: Resource Profiles

These define constraints on FHIR resources for systems conforming to this implementation guide.

MII PR Labor Laboranforderung

Dieses Profil beschreibt eine Laboranforderung in der Medizininformatik-Initiative.

MII PR Labor Laborbefund

Dieses Profil beschreibt einen Laborbefund in der Medizininformatik-Initiative.

MII PR Labor Laboruntersuchung

Dieses Profil beschreibt eine Laborergebnis in der Medizininformatik-Initiative.

Structures: Extension Definitions

These define constraints on FHIR data types for systems conforming to this implementation guide.

MII EX Labor Interpretationsbeeinflussende Eigenschaft

Interpretationsbeeinflussenden Eigenschaft einer Laboruntersuchung oder Probe.

MII EX Labor Quelle Klinisches Bezugsdatum

Quelle des klinischen Bezugsdatums

Terminology: Value Sets

These define sets of codes used by systems conforming to this implementation guide.

MII VS Labor Identifier Type Codes

Type-Codes, um zu bestimmen, welcher Identifier für einen bestimmten Zweck zu verwenden ist.

MII VS Labor Interpretation

Kategorische Bewertung eines Laborwertes. Eingeschränkte Auswahl aus HL7 v3 ObservationInterpretation auf die im Laborkontext sinnvollen Konzepte.

MII VS Labor Interpretationsbeeinflussende Eigenschaften SNOMEDCT

Codes zur Beschreibung von interpretationsbeeinflussenden Eigenschaften der Laboruntersuchung oder Probe.

MII VS Labor Laborbereich

Laboruntersuchungen werden in diagnostische Fachbereiche (untersuchende Fachbereiche) gruppiert.

MII VS Labor Laborergbenis Semiquantitativ

Kodierung für semi-quantitative Laborergebnisse

MII VS Labor Laborergebnis Codiert

Kodierte Laborergebnisse, umfasst qualitative und semiquantitative Ergebnisse

MII VS Labor Laborergebnis Qualitativ

Kodierung für qualitative Laborergebnisse

MII VS Labor Order Codes

Kodierung der Beauftragungen von Laboruntersuchungen

MII VS Labor Quelle klinisches Bezugsdatum

Kodierung der Quelle des klinischen Bezugsdatums

Example: Example Instances

These are example instances that show what data produced and consumed by systems conforming with this implementation guide might look like.

Laboratory order: full blood count

A laboratory order for a full blood count, the request the reported tests were performed for.

Laboratory report: creatinine

A laboratory report grouping the laboratory test examples of this guide.

Laboratory result: albumin in 24-hour urine

Albumin in 24-hour urine, an excretion rate stated as a valueQuantity with the composed UCUM unit mg/(24.h). A valueRatio would carry the same information, but cannot be found with the value-quantity search parameter.

Laboratory result: creatinine

A quantitative creatinine test: valueQuantity with a reference range and a coded interpretation.

Laboratory result: creatinine without a value (Data Absent Reason)

A creatinine test carrying no value: dataAbsentReason states why, alongside a reference range and an interpretation.

Laboratory result: epithelial cells in urine sediment (range)

Epithelial cells in urine sediment, a test whose result is a range rather than a single value (valueRange).

mii-exa-labor-encounter

Minimal reference encounter for the laboratory examples.

mii-exa-labor-organization

Minimal reference organization (performing laboratory) for the laboratory examples.

mii-exa-labor-patient

Minimal reference patient for the laboratory examples.

mii-exa-labor-specimen

Minimal reference specimen for the laboratory examples.

Other

These are resources that are used within this implementation guide that do not fit into one of the other categories.

Expansion Parameters Manifest

Pinned code system versions every ValueSet in this IG is expanded against.