MII IG Laborbefund
2027.0.0-ballot -
Germany
MII IG Laborbefund - Local Development build (v2027.0.0-ballot) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Contents:
This page provides a list of the FHIR artifacts defined as part of this implementation guide.
The following artifacts define the specific capabilities that different types of systems are expected to have in order to comply with this implementation guide. Systems conforming to this implementation guide are expected to declare conformance to one or more of the following capability statements.
| MII CPS Labor CapabilityStatement |
Das vorliegende CapabilityStatement beschreibt alle verpflichtenden Interaktionen die ein konformes System unterstützen muss, um das Modul Labor der Medizininformatik Initiative zu implementieren. |
These define data models that represent the domain covered by this implementation guide in more business-friendly terms than the underlying FHIR resources.
| MII LM Labor |
Logische Repräsentation des Basismoduls Labor |
These define constraints on FHIR resources for systems conforming to this implementation guide.
| MII PR Labor Laboranforderung |
Dieses Profil beschreibt eine Laboranforderung in der Medizininformatik-Initiative. |
| MII PR Labor Laborbefund |
Dieses Profil beschreibt einen Laborbefund in der Medizininformatik-Initiative. |
| MII PR Labor Laboruntersuchung |
Dieses Profil beschreibt eine Laborergebnis in der Medizininformatik-Initiative. |
These define constraints on FHIR data types for systems conforming to this implementation guide.
| MII EX Labor Interpretationsbeeinflussende Eigenschaft |
Interpretationsbeeinflussenden Eigenschaft einer Laboruntersuchung oder Probe. |
| MII EX Labor Quelle Klinisches Bezugsdatum |
Quelle des klinischen Bezugsdatums |
These define sets of codes used by systems conforming to this implementation guide.
| MII VS Labor Identifier Type Codes |
Type-Codes, um zu bestimmen, welcher Identifier für einen bestimmten Zweck zu verwenden ist. |
| MII VS Labor Interpretation |
Kategorische Bewertung eines Laborwertes. Eingeschränkte Auswahl aus HL7 v3 ObservationInterpretation auf die im Laborkontext sinnvollen Konzepte. |
| MII VS Labor Interpretationsbeeinflussende Eigenschaften SNOMEDCT |
Codes zur Beschreibung von interpretationsbeeinflussenden Eigenschaften der Laboruntersuchung oder Probe. |
| MII VS Labor Laborbereich |
Laboruntersuchungen werden in diagnostische Fachbereiche (untersuchende Fachbereiche) gruppiert. |
| MII VS Labor Laborergbenis Semiquantitativ |
Kodierung für semi-quantitative Laborergebnisse |
| MII VS Labor Laborergebnis Codiert |
Kodierte Laborergebnisse, umfasst qualitative und semiquantitative Ergebnisse |
| MII VS Labor Laborergebnis Qualitativ |
Kodierung für qualitative Laborergebnisse |
| MII VS Labor Order Codes |
Kodierung der Beauftragungen von Laboruntersuchungen |
| MII VS Labor Quelle klinisches Bezugsdatum |
Kodierung der Quelle des klinischen Bezugsdatums |
These are example instances that show what data produced and consumed by systems conforming with this implementation guide might look like.
| Laboratory order: full blood count |
A laboratory order for a full blood count, the request the reported tests were performed for. |
| Laboratory report: creatinine |
A laboratory report grouping the laboratory test examples of this guide. |
| Laboratory result: albumin in 24-hour urine |
Albumin in 24-hour urine, an excretion rate stated as a valueQuantity with the composed UCUM unit mg/(24.h). A valueRatio would carry the same information, but cannot be found with the value-quantity search parameter. |
| Laboratory result: creatinine |
A quantitative creatinine test: valueQuantity with a reference range and a coded interpretation. |
| Laboratory result: creatinine without a value (Data Absent Reason) |
A creatinine test carrying no value: dataAbsentReason states why, alongside a reference range and an interpretation. |
| Laboratory result: epithelial cells in urine sediment (range) |
Epithelial cells in urine sediment, a test whose result is a range rather than a single value (valueRange). |
| mii-exa-labor-encounter |
Minimal reference encounter for the laboratory examples. |
| mii-exa-labor-organization |
Minimal reference organization (performing laboratory) for the laboratory examples. |
| mii-exa-labor-patient |
Minimal reference patient for the laboratory examples. |
| mii-exa-labor-specimen |
Minimal reference specimen for the laboratory examples. |
These are resources that are used within this implementation guide that do not fit into one of the other categories.
| Expansion Parameters Manifest |
Pinned code system versions every ValueSet in this IG is expanded against. |