MII IG Kerndatensatz-Modul Onkologie
2027.0.0-ballot.1 - Germany

This page is part of the MII IG Kerndatensatz-Modul Onkologie (v2027.0.0-ballot.1: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Resource Profile: MII PR Onkologie Melanom Sicherheitsabstand

Official URL: https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/StructureDefinition/mii-pr-onko-melanom-sicherheitsabstand Version: 2027.0.0-ballot.1
Active as of 2026-09-15 Computable Name: MII_PR_Onko_Melanom_Sicherheitsabstand

Dieses Profil beschreibt den minimalen Sicherheitsabstand zum Primärtumor beim Malignen Melanom basierend auf oBDS Feld MM1. Bei nicht beurteilbaren Fällen (oBDS Wert -1) wird dataAbsentReason verwendet statt valueQuantity.

Content

This profile describes the minimal safety margin to the primary tumor in malignant melanoma according to oBDS MM1. This measurement is performed after definitive surgical intervention and indicates the minimal distance of the melanoma to the nearest lateral surgical resection margin in the excision specimen. A value of 0 corresponds to a local R1 or R2 resection status.

The profile is based on a FHIR Observation resource and uses SNOMED CT for standardized coding of the safety margin measurement. The distance is given as a Quantity value in millimeters (mm).


The safety margin measurement is an important surgical observation in melanoma:

  • refers via Observation.focus to the primary diagnosis (MII_PR_Onko_Diagnose_Primaertumor)
  • refers via Observation.subject to the patient (Patient resource)
  • can be linked via Observation.encounter to a specific treatment case

oBDS context

The safety margin measurement corresponds to the oBDS data field MM1 "Minimal safety margin to the primary tumor" and is documented in millimeters. This measurement is essential for assessing the completeness of tumor resection and the prognosis in melanoma.

Note on coding not-assessable cases: According to oBDS, the safety margin can take the following values:

  • -1: not assessable → In FHIR, dataAbsentReason is used (e.g. "unknown" or "not-asked") instead of valueQuantity
  • 0: no safety margin (R1/R2 resection) → valueQuantity.value = 0
  • n: safety margin in mm → valueQuantity.value = n

The profile contains an invariant ensuring that either valueQuantity or dataAbsentReason must be present.

Terminology binding

The profile uses SNOMED CT code 396511007 "Distance of in situ melanoma from closest lateral surgical margin in excised specimen of skin (observable entity)" for standardized coding of the safety margin measurement. The value is given as a UCUM-compliant Quantity in millimeters (mm).


Mapping dataset to FHIR

The mapping of the dataset fields is documented in the logical model: MII LM Onkologie Organspezifische Zusatzmodule.


Mapping Uniform Oncological Base Dataset (oBDS) to FHIR

The oBDS mappings are recorded in the artefact view of this profile: MII PR Onkologie Melanom Sicherheitsabstand.

Examples

mii-exa-onko-melanom-sicherheitsabstand

Usages:

You can also check for usages in the FHIR IG Statistics

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots, and their representations.

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Observation C 0..* Observation Measurements and simple assertions
Constraints: obs-6, obs-7, mii-onko-melanom-sicherheitsabstand-1
... meta Σ 0..1 Meta Metadata about the resource
.... profile SΣ 0..* canonical(StructureDefinition) Profiles this resource claims to conform to
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... code SΣ 1..1 CodeableConcept Sicherheitsabstand Primärtumor
Binding: LOINCCodes (example): Codes identifying names of simple observations.
.... coding Σ 0..* Coding Code defined by a terminology system

Required Pattern: At least the following
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
..... version 0..1 string Version of the system - if relevant
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 396511007
..... display 1..1 string Representation defined by the system
Fixed Value: Distance of in situ melanoma from closest lateral surgical margin in excised specimen of skin (observable entity)
..... userSelected 0..1 boolean If this coding was chosen directly by the user
... subject SΣ 1..1 Reference(Patient) Who and/or what the observation is about
... focus SΣ 0..* Reference(MII PR Onkologie Diagnose Primärtumor) What the observation is about, when it is not about the subject of record
... encounter SΣ 0..1 Reference(Encounter) Healthcare event during which this observation is made
... effective[x] SΣ 0..1 dateTime Datum der Messung
... value[x] SΣC 0..1 Quantity Sicherheitsabstand in mm
.... value SΣ 0..1 decimal Numerical value (with implicit precision)
.... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.
.... unit SΣ 1..1 string Unit representation
Required Pattern: mm
.... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
.... code SΣ 1..1 code Coded form of the unit
Required Pattern: mm
... dataAbsentReason SC 0..1 CodeableConcept Grund für fehlende Messung
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Observation.status Base required ObservationStatus 📍4.0.1 FHIR Std.
Observation.code Base example LOINC Codes 📍4.0.1 FHIR Std.
Observation.value[x].​comparator Base required QuantityComparator 📍4.0.1 FHIR Std.
Observation.dataAbsentReason Base extensible DataAbsentReason 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Observation If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Observation If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Observation If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Observation If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Observation A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()
mii-onko-melanom-sicherheitsabstand-1 error Observation Entweder muss valueQuantity oder dataAbsentReason vorhanden sein valueQuantity.exists() or dataAbsentReason.exists()
obs-6 error Observation dataAbsentReason SHALL only be present if Observation.value[x] is not present dataAbsentReason.empty() or value.empty()
obs-7 error Observation If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Observation C 0..* Observation Measurements and simple assertions
Constraints: mii-onko-melanom-sicherheitsabstand-1
... meta
.... profile S 0..* canonical(StructureDefinition) Profiles this resource claims to conform to
... code S 1..1 CodeableConcept Sicherheitsabstand Primärtumor
.... coding 0..* Coding Code defined by a terminology system
Required Pattern: At least the following
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 396511007
..... display 1..1 string Representation defined by the system
Fixed Value: Distance of in situ melanoma from closest lateral surgical margin in excised specimen of skin (observable entity)
... subject S 1..1 Reference(Patient) Who and/or what the observation is about
... encounter S 0..1 Reference(Encounter) Healthcare event during which this observation is made
... effective[x] S 0..1 dateTime Datum der Messung
... value[x] S 0..1 Quantity Sicherheitsabstand in mm
.... value S 0..1 decimal Numerical value (with implicit precision)
.... unit S 1..1 string Unit representation
Required Pattern: mm
.... system S 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
.... code S 1..1 code Coded form of the unit
Required Pattern: mm
... dataAbsentReason S 0..1 CodeableConcept Grund für fehlende Messung

doco Documentation for this format

Constraints

Id Grade Path(s) Description Expression
mii-onko-melanom-sicherheitsabstand-1 error Observation Entweder muss valueQuantity oder dataAbsentReason vorhanden sein valueQuantity.exists() or dataAbsentReason.exists()
NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Observation C 0..* Observation Measurements and simple assertions
Constraints: obs-6, obs-7, mii-onko-melanom-sicherheitsabstand-1
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... versionId Σ 0..1 id Version specific identifier
.... lastUpdated Σ 0..1 instant When the resource version last changed
.... source Σ 0..1 uri Identifies where the resource comes from
.... profile SΣ 0..* canonical(StructureDefinition) Profiles this resource claims to conform to
.... security Σ 0..* Coding Security Labels applied to this resource
Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System.
.... tag Σ 0..* Coding Tags applied to this resource
Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones".
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.
Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier Σ 0..* Identifier Business Identifier for observation
... basedOn Σ 0..* Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) Fulfills plan, proposal or order
... partOf Σ 0..* Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Part of referenced event
... status ?!Σ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.
... category 0..* CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.
... code SΣ 1..1 CodeableConcept Sicherheitsabstand Primärtumor
Binding: LOINCCodes (example): Codes identifying names of simple observations.
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... coding Σ 0..* Coding Code defined by a terminology system

Required Pattern: At least the following
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
..... version 0..1 string Version of the system - if relevant
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 396511007
..... display 1..1 string Representation defined by the system
Fixed Value: Distance of in situ melanoma from closest lateral surgical margin in excised specimen of skin (observable entity)
..... userSelected 0..1 boolean If this coding was chosen directly by the user
.... text Σ 0..1 string Plain text representation of the concept
... subject SΣ 1..1 Reference(Patient) Who and/or what the observation is about
... focus SΣ 0..* Reference(MII PR Onkologie Diagnose Primärtumor) What the observation is about, when it is not about the subject of record
... encounter SΣ 0..1 Reference(Encounter) Healthcare event during which this observation is made
... effective[x] SΣ 0..1 dateTime Datum der Messung
... issued Σ 0..1 instant Date/Time this version was made available
... performer Σ 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Who is responsible for the observation
... value[x] SΣC 0..1 Quantity Sicherheitsabstand in mm
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... value SΣ 0..1 decimal Numerical value (with implicit precision)
.... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.
.... unit SΣ 1..1 string Unit representation
Required Pattern: mm
.... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
.... code SΣ 1..1 code Coded form of the unit
Required Pattern: mm
... dataAbsentReason SC 0..1 CodeableConcept Grund für fehlende Messung
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.
... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.
... note 0..* Annotation Comments about the observation
... bodySite 0..1 CodeableConcept Observed body part
Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.
... method 0..1 CodeableConcept How it was done
Binding: ObservationMethods (example): Methods for simple observations.
... specimen 0..1 Reference(Specimen) Specimen used for this observation
... device 0..1 Reference(Device | DeviceMetric) (Measurement) Device
... referenceRange C 0..* BackboneElement Provides guide for interpretation
Constraints: obs-3
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... low C 0..1 SimpleQuantity(4.0.1) Low Range, if relevant
.... high C 0..1 SimpleQuantity(4.0.1) High Range, if relevant
.... type 0..1 CodeableConcept Reference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.
.... appliesTo 0..* CodeableConcept Reference range population
Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.
.... age 0..1 Range Applicable age range, if relevant
.... text 0..1 string Text based reference range in an observation
... hasMember Σ 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Related resource that belongs to the Observation group
... derivedFrom Σ 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Related measurements the observation is made from
... component Σ 0..* BackboneElement Component results
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... code Σ 1..1 CodeableConcept Type of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.
.... value[x] Σ 0..1 Actual component result
..... valueQuantity Quantity
..... valueCodeableConcept CodeableConcept
..... valueString string
..... valueBoolean boolean
..... valueInteger integer
..... valueRange Range
..... valueRatio Ratio
..... valueSampledData SampledData
..... valueTime time
..... valueDateTime dateTime
..... valuePeriod Period
.... dataAbsentReason C 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.
.... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.
.... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Observation.meta.security Base extensible SecurityLabels 📍4.0.1 FHIR Std.
Observation.meta.tag Base example Common Tags 📍4.0.1 FHIR Std.
Observation.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Observation.status Base required ObservationStatus 📍4.0.1 FHIR Std.
Observation.category Base preferred Observation Category Codes 📍4.0.1 FHIR Std.
Observation.code Base example LOINC Codes 📍4.0.1 FHIR Std.
Observation.value[x].​comparator Base required QuantityComparator 📍4.0.1 FHIR Std.
Observation.dataAbsentReason Base extensible DataAbsentReason 📍4.0.1 FHIR Std.
Observation.interpretation Base extensible Observation Interpretation Codes 📍4.0.1 FHIR Std.
Observation.bodySite Base example SNOMED CT Body Structures 📍4.0.1 FHIR Std.
Observation.method Base example Observation Methods 📍4.0.1 FHIR Std.
Observation.referenceRange.​type Base preferred Observation Reference Range Meaning Codes 📍4.0.1 FHIR Std.
Observation.referenceRange.​appliesTo Base example Observation Reference Range Applies To Codes 📍4.0.1 FHIR Std.
Observation.component.​code Base example LOINC Codes 📍4.0.1 FHIR Std.
Observation.component.​dataAbsentReason Base extensible DataAbsentReason 📍4.0.1 FHIR Std.
Observation.component.​interpretation Base extensible Observation Interpretation Codes 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Observation If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Observation If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Observation If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Observation If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Observation A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()
mii-onko-melanom-sicherheitsabstand-1 error Observation Entweder muss valueQuantity oder dataAbsentReason vorhanden sein valueQuantity.exists() or dataAbsentReason.exists()
obs-3 error Observation.referenceRange Must have at least a low or a high or text low.exists() or high.exists() or text.exists()
obs-6 error Observation dataAbsentReason SHALL only be present if Observation.value[x] is not present dataAbsentReason.empty() or value.empty()
obs-7 error Observation If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()

Summary

Mandatory: 1 element(3 nested mandatory elements)
Must-Support: 12 elements
Fixed: 1 element

Structures

This structure refers to these other structures:

Key Elements View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Observation C 0..* Observation Measurements and simple assertions
Constraints: obs-6, obs-7, mii-onko-melanom-sicherheitsabstand-1
... meta Σ 0..1 Meta Metadata about the resource
.... profile SΣ 0..* canonical(StructureDefinition) Profiles this resource claims to conform to
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... code SΣ 1..1 CodeableConcept Sicherheitsabstand Primärtumor
Binding: LOINCCodes (example): Codes identifying names of simple observations.
.... coding Σ 0..* Coding Code defined by a terminology system

Required Pattern: At least the following
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
..... version 0..1 string Version of the system - if relevant
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 396511007
..... display 1..1 string Representation defined by the system
Fixed Value: Distance of in situ melanoma from closest lateral surgical margin in excised specimen of skin (observable entity)
..... userSelected 0..1 boolean If this coding was chosen directly by the user
... subject SΣ 1..1 Reference(Patient) Who and/or what the observation is about
... focus SΣ 0..* Reference(MII PR Onkologie Diagnose Primärtumor) What the observation is about, when it is not about the subject of record
... encounter SΣ 0..1 Reference(Encounter) Healthcare event during which this observation is made
... effective[x] SΣ 0..1 dateTime Datum der Messung
... value[x] SΣC 0..1 Quantity Sicherheitsabstand in mm
.... value SΣ 0..1 decimal Numerical value (with implicit precision)
.... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.
.... unit SΣ 1..1 string Unit representation
Required Pattern: mm
.... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
.... code SΣ 1..1 code Coded form of the unit
Required Pattern: mm
... dataAbsentReason SC 0..1 CodeableConcept Grund für fehlende Messung
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Observation.status Base required ObservationStatus 📍4.0.1 FHIR Std.
Observation.code Base example LOINC Codes 📍4.0.1 FHIR Std.
Observation.value[x].​comparator Base required QuantityComparator 📍4.0.1 FHIR Std.
Observation.dataAbsentReason Base extensible DataAbsentReason 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Observation If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Observation If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Observation If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Observation If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Observation A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()
mii-onko-melanom-sicherheitsabstand-1 error Observation Entweder muss valueQuantity oder dataAbsentReason vorhanden sein valueQuantity.exists() or dataAbsentReason.exists()
obs-6 error Observation dataAbsentReason SHALL only be present if Observation.value[x] is not present dataAbsentReason.empty() or value.empty()
obs-7 error Observation If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()

Differential View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Observation C 0..* Observation Measurements and simple assertions
Constraints: mii-onko-melanom-sicherheitsabstand-1
... meta
.... profile S 0..* canonical(StructureDefinition) Profiles this resource claims to conform to
... code S 1..1 CodeableConcept Sicherheitsabstand Primärtumor
.... coding 0..* Coding Code defined by a terminology system
Required Pattern: At least the following
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 396511007
..... display 1..1 string Representation defined by the system
Fixed Value: Distance of in situ melanoma from closest lateral surgical margin in excised specimen of skin (observable entity)
... subject S 1..1 Reference(Patient) Who and/or what the observation is about
... encounter S 0..1 Reference(Encounter) Healthcare event during which this observation is made
... effective[x] S 0..1 dateTime Datum der Messung
... value[x] S 0..1 Quantity Sicherheitsabstand in mm
.... value S 0..1 decimal Numerical value (with implicit precision)
.... unit S 1..1 string Unit representation
Required Pattern: mm
.... system S 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
.... code S 1..1 code Coded form of the unit
Required Pattern: mm
... dataAbsentReason S 0..1 CodeableConcept Grund für fehlende Messung

doco Documentation for this format

Constraints

Id Grade Path(s) Description Expression
mii-onko-melanom-sicherheitsabstand-1 error Observation Entweder muss valueQuantity oder dataAbsentReason vorhanden sein valueQuantity.exists() or dataAbsentReason.exists()

Snapshot ViewView

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Observation C 0..* Observation Measurements and simple assertions
Constraints: obs-6, obs-7, mii-onko-melanom-sicherheitsabstand-1
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... versionId Σ 0..1 id Version specific identifier
.... lastUpdated Σ 0..1 instant When the resource version last changed
.... source Σ 0..1 uri Identifies where the resource comes from
.... profile SΣ 0..* canonical(StructureDefinition) Profiles this resource claims to conform to
.... security Σ 0..* Coding Security Labels applied to this resource
Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System.
.... tag Σ 0..* Coding Tags applied to this resource
Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones".
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.
Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier Σ 0..* Identifier Business Identifier for observation
... basedOn Σ 0..* Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) Fulfills plan, proposal or order
... partOf Σ 0..* Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Part of referenced event
... status ?!Σ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.
... category 0..* CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.
... code SΣ 1..1 CodeableConcept Sicherheitsabstand Primärtumor
Binding: LOINCCodes (example): Codes identifying names of simple observations.
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... coding Σ 0..* Coding Code defined by a terminology system

Required Pattern: At least the following
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
..... version 0..1 string Version of the system - if relevant
..... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 396511007
..... display 1..1 string Representation defined by the system
Fixed Value: Distance of in situ melanoma from closest lateral surgical margin in excised specimen of skin (observable entity)
..... userSelected 0..1 boolean If this coding was chosen directly by the user
.... text Σ 0..1 string Plain text representation of the concept
... subject SΣ 1..1 Reference(Patient) Who and/or what the observation is about
... focus SΣ 0..* Reference(MII PR Onkologie Diagnose Primärtumor) What the observation is about, when it is not about the subject of record
... encounter SΣ 0..1 Reference(Encounter) Healthcare event during which this observation is made
... effective[x] SΣ 0..1 dateTime Datum der Messung
... issued Σ 0..1 instant Date/Time this version was made available
... performer Σ 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Who is responsible for the observation
... value[x] SΣC 0..1 Quantity Sicherheitsabstand in mm
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... value SΣ 0..1 decimal Numerical value (with implicit precision)
.... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.
.... unit SΣ 1..1 string Unit representation
Required Pattern: mm
.... system SΣC 1..1 uri System that defines coded unit form
Fixed Value: http://unitsofmeasure.org
.... code SΣ 1..1 code Coded form of the unit
Required Pattern: mm
... dataAbsentReason SC 0..1 CodeableConcept Grund für fehlende Messung
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.
... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.
... note 0..* Annotation Comments about the observation
... bodySite 0..1 CodeableConcept Observed body part
Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.
... method 0..1 CodeableConcept How it was done
Binding: ObservationMethods (example): Methods for simple observations.
... specimen 0..1 Reference(Specimen) Specimen used for this observation
... device 0..1 Reference(Device | DeviceMetric) (Measurement) Device
... referenceRange C 0..* BackboneElement Provides guide for interpretation
Constraints: obs-3
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... low C 0..1 SimpleQuantity(4.0.1) Low Range, if relevant
.... high C 0..1 SimpleQuantity(4.0.1) High Range, if relevant
.... type 0..1 CodeableConcept Reference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.
.... appliesTo 0..* CodeableConcept Reference range population
Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.
.... age 0..1 Range Applicable age range, if relevant
.... text 0..1 string Text based reference range in an observation
... hasMember Σ 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Related resource that belongs to the Observation group
... derivedFrom Σ 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Related measurements the observation is made from
... component Σ 0..* BackboneElement Component results
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... code Σ 1..1 CodeableConcept Type of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.
.... value[x] Σ 0..1 Actual component result
..... valueQuantity Quantity
..... valueCodeableConcept CodeableConcept
..... valueString string
..... valueBoolean boolean
..... valueInteger integer
..... valueRange Range
..... valueRatio Ratio
..... valueSampledData SampledData
..... valueTime time
..... valueDateTime dateTime
..... valuePeriod Period
.... dataAbsentReason C 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.
.... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.
.... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Observation.meta.security Base extensible SecurityLabels 📍4.0.1 FHIR Std.
Observation.meta.tag Base example Common Tags 📍4.0.1 FHIR Std.
Observation.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Observation.status Base required ObservationStatus 📍4.0.1 FHIR Std.
Observation.category Base preferred Observation Category Codes 📍4.0.1 FHIR Std.
Observation.code Base example LOINC Codes 📍4.0.1 FHIR Std.
Observation.value[x].​comparator Base required QuantityComparator 📍4.0.1 FHIR Std.
Observation.dataAbsentReason Base extensible DataAbsentReason 📍4.0.1 FHIR Std.
Observation.interpretation Base extensible Observation Interpretation Codes 📍4.0.1 FHIR Std.
Observation.bodySite Base example SNOMED CT Body Structures 📍4.0.1 FHIR Std.
Observation.method Base example Observation Methods 📍4.0.1 FHIR Std.
Observation.referenceRange.​type Base preferred Observation Reference Range Meaning Codes 📍4.0.1 FHIR Std.
Observation.referenceRange.​appliesTo Base example Observation Reference Range Applies To Codes 📍4.0.1 FHIR Std.
Observation.component.​code Base example LOINC Codes 📍4.0.1 FHIR Std.
Observation.component.​dataAbsentReason Base extensible DataAbsentReason 📍4.0.1 FHIR Std.
Observation.component.​interpretation Base extensible Observation Interpretation Codes 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Observation If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Observation If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Observation If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Observation If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Observation A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()
mii-onko-melanom-sicherheitsabstand-1 error Observation Entweder muss valueQuantity oder dataAbsentReason vorhanden sein valueQuantity.exists() or dataAbsentReason.exists()
obs-3 error Observation.referenceRange Must have at least a low or a high or text low.exists() or high.exists() or text.exists()
obs-6 error Observation dataAbsentReason SHALL only be present if Observation.value[x] is not present dataAbsentReason.empty() or value.empty()
obs-7 error Observation If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()

Summary

Mandatory: 1 element(3 nested mandatory elements)
Must-Support: 12 elements
Fixed: 1 element

Structures

This structure refers to these other structures:

 

Other representations of profile: CSV, Excel, Schematron