MII IG Kerndatensatz-Modul Molekulares Tumorboard
2027.0.0-ballot.1 -
Germany
This page is part of the MII Implementation Guide Molecular Tumor Board (v2027.0.0-ballot.1: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
| Offizielle URL: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-pr-mtb-panel-devicedefinition | Version: 2027.0.0-ballot.1 | |||
| Active Stand: 2026-09-15 | Maschinenlesbarer Name: MII_PR_MTB_Panel_DeviceDefinition | |||
Katalog-Template eines Sequenzier-Panel-Produkts (Genpanel): Hersteller, Produktname/Version, analytische Faehigkeiten und Genliste(n). Konkrete Geraete/Kits einer Einrichtung verweisen via Device.definition auf ihr Template.
Written during migration - review before release. Neuer Modellierungsvorschlag (2026-09-14): der Panel-Produktkatalog als DeviceDefinition-Templates, generiert aus dem Panel-Metadaten-Inventar des Modulteams. Vor Release prüfen.
Dieses Profil trägt den Sequenzier-Panel-Produktkatalog auf Definitionsebene: je Panel-Produkt ein DeviceDefinition-Template (Hersteller, Produktname/Version, analytische Fähigkeiten und die Genliste(n) des Panels als kanonische Referenzen auf HGNC-ValueSets — nach SNV- und Fusions-Scope getrennt, wo das Produkt sie unterscheidet).
Die konkrete Geräte-/Kit-Instanz einer Einrichtung verweist via
Device.definition auf ihr Template und hängt wie bisher über die
Genomics-Reporting-Extension genomic-study-analysis-device am
Sequenzier-Workflow.
Der mitgelieferte Katalog umfasst elf Produkte (Oncomine Focus/Focus Plus, Qiagen DHS-3501Z, Agilent MH IVD 600+ und SureSelect Cancer CGP, DKTK/MASTER WGS, generisches WGS, FusionPlex Archer Lung V2, TCM NGS, Basic-NGS, TruSight Oncology 500) mit neun Genlisten-ValueSets (17–602 Gene, kodiert mit stabilen HGNC-IDs; Displays sind die aktuellen Approved-Symbole, veraltete Quellsymbole wurden gemappt und annotiert).
Usages:
You can also check for usages in the FHIR IG Statistics
Beschreibung von Profilen, Differentials, Snapshots und deren Repräsentationen.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | DeviceDefinition | An instance of a medical-related component of a medical device | |
![]() ![]() |
SΣ | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() |
SΣ | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..* | (Complex) | MII EX MTB Panel Gene List URL: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-ex-mtb-panel-gene-list |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
S | 0..1 | Name of device manufacturer | |
![]() ![]() ![]() |
string | |||
![]() ![]() ![]() |
Reference(Organization) | |||
![]() ![]() |
S | 1..* | BackboneElement | A name given to the device to identify it |
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() |
S | 1..1 | string | The name of the device |
![]() ![]() ![]() |
S | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. |
![]() ![]() |
S | 1..1 | CodeableConcept | What kind of device or device system this is Binding: FHIRDeviceTypes (example): Type of device e.g. according to official classification. Required Pattern: At least the following |
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/CodeSystem/mii-cs-mtb-genomicanalysis-devicefunction | |
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: gene-panel | |
![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() |
S | 0..* | string | Available versions |
![]() ![]() |
S | 0..* | BackboneElement | Device capabilities |
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of capability Binding: MII VS MTB Panel Capability (required) |
![]() ![]() |
S | 0..1 | uri | Herstellerseite / Produktdokumentation |
![]() ![]() |
S | 0..* | Annotation | Device notes and comments |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceDefinition.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.type | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.capability.type | Base | required | MII VS MTB Panel Capability | 📦2027.0.0-ballot.1 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | DeviceDefinition | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | DeviceDefinition | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | DeviceDefinition | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | DeviceDefinition | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | DeviceDefinition | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Diese Struktur ist abgeleitet von DeviceDefinition
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | DeviceDefinition | An instance of a medical-related component of a medical device | |
![]() ![]() |
S | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() |
S | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..* | (Complex) | MII EX MTB Panel Gene List URL: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-ex-mtb-panel-gene-list |
![]() ![]() |
S | 0..1 | string, Reference(Organization) | Name of device manufacturer |
![]() ![]() |
S | 1..* | BackboneElement | A name given to the device to identify it |
![]() ![]() ![]() |
S | 1..1 | string | The name of the device |
![]() ![]() ![]() |
S | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other |
![]() ![]() |
S | 1..1 | CodeableConcept | What kind of device or device system this is Required Pattern: At least the following |
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/CodeSystem/mii-cs-mtb-genomicanalysis-devicefunction | |
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: gene-panel | |
![]() ![]() |
S | 0..* | string | Available versions |
![]() ![]() |
S | 0..* | BackboneElement | Device capabilities |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of capability Binding: MII VS MTB Panel Capability (required) |
![]() ![]() |
S | 0..1 | uri | Herstellerseite / Produktdokumentation |
![]() ![]() |
S | 0..* | Annotation | Device notes and comments |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceDefinition.capability.type | Base | required | MII VS MTB Panel Capability | 📦2027.0.0-ballot.1 | This IG |
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
0..* | DeviceDefinition | An instance of a medical-related component of a medical device | |||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
SΣ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Version specific identifier | ||||
![]() ![]() ![]() |
Σ | 0..1 | instant | When the resource version last changed | ||||
![]() ![]() ![]() |
Σ | 0..1 | uri | Identifies where the resource comes from | ||||
![]() ![]() ![]() |
SΣ | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to | ||||
![]() ![]() ![]() |
Σ | 0..* | Coding | Security Labels applied to this resource Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System. | ||||
![]() ![]() ![]() |
Σ | 0..* | Coding | Tags applied to this resource Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
S | 0..* | (Complex) | MII EX MTB Panel Gene List URL: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-ex-mtb-panel-gene-list | ||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
0..* | Identifier | Instance identifier | |||||
![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | string | The identifier that is to be associated with every Device that references this DeviceDefintiion for the issuer and jurisdication porvided in the DeviceDefinition.udiDeviceIdentifier | |||||
![]() ![]() ![]() |
1..1 | uri | The organization that assigns the identifier algorithm | |||||
![]() ![]() ![]() |
1..1 | uri | The jurisdiction to which the deviceIdentifier applies | |||||
![]() ![]() |
S | 0..1 | Name of device manufacturer | |||||
![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() |
Reference(Organization) | |||||||
![]() ![]() |
S | 1..* | BackboneElement | A name given to the device to identify it | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
S | 1..1 | string | The name of the device | ||||
![]() ![]() ![]() |
S | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | ||||
![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() |
S | 1..1 | CodeableConcept | What kind of device or device system this is Binding: FHIRDeviceTypes (example): Type of device e.g. according to official classification. Required Pattern: At least the following | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/CodeSystem/mii-cs-mtb-genomicanalysis-devicefunction | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: gene-panel | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | string | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() |
S | 0..* | string | Available versions | ||||
![]() ![]() |
Σ | 0..* | CodeableConcept | Safety characteristics of the device Binding: DeviceSafety (example) | ||||
![]() ![]() |
0..* | ProductShelfLife | Shelf Life and storage information | |||||
![]() ![]() |
0..1 | ProdCharacteristic | Dimensions, color etc. | |||||
![]() ![]() |
0..* | CodeableConcept | Language code for the human-readable text strings produced by the device (all supported) | |||||
![]() ![]() |
S | 0..* | BackboneElement | Device capabilities | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of capability Binding: MII VS MTB Panel Capability (required) | ||||
![]() ![]() ![]() |
0..* | CodeableConcept | Description of capability | |||||
![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() |
S | 0..1 | uri | Herstellerseite / Produktdokumentation | ||||
![]() ![]() |
S | 0..* | Annotation | Device notes and comments | ||||
![]() ![]() |
0..1 | Quantity | The quantity of the device present in the packaging (e.g. the number of devices present in a pack, or the number of devices in the same package of the medicinal product) | |||||
![]() ![]() |
Σ | 0..1 | Reference(DeviceDefinition) | The parent device it can be part of | ||||
![]() ![]() |
0..* | BackboneElement | A substance used to create the material(s) of which the device is made | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The substance | |||||
![]() ![]() ![]() |
0..1 | boolean | Indicates an alternative material of the device | |||||
![]() ![]() ![]() |
0..1 | boolean | Whether the substance is a known or suspected allergen | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceDefinition.meta.security | Base | extensible | SecurityLabels | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.meta.tag | Base | example | Common Tags | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.type | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.safety | Base | example | Device safety | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.capability.type | Base | required | MII VS MTB Panel Capability | 📦2027.0.0-ballot.1 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | DeviceDefinition | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | DeviceDefinition | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | DeviceDefinition | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | DeviceDefinition | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | DeviceDefinition | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Diese Struktur ist abgeleitet von DeviceDefinition
Schlüsselelemente-Ansicht
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | DeviceDefinition | An instance of a medical-related component of a medical device | |
![]() ![]() |
SΣ | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() |
SΣ | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..* | (Complex) | MII EX MTB Panel Gene List URL: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-ex-mtb-panel-gene-list |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
S | 0..1 | Name of device manufacturer | |
![]() ![]() ![]() |
string | |||
![]() ![]() ![]() |
Reference(Organization) | |||
![]() ![]() |
S | 1..* | BackboneElement | A name given to the device to identify it |
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() |
S | 1..1 | string | The name of the device |
![]() ![]() ![]() |
S | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. |
![]() ![]() |
S | 1..1 | CodeableConcept | What kind of device or device system this is Binding: FHIRDeviceTypes (example): Type of device e.g. according to official classification. Required Pattern: At least the following |
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/CodeSystem/mii-cs-mtb-genomicanalysis-devicefunction | |
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: gene-panel | |
![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() |
S | 0..* | string | Available versions |
![]() ![]() |
S | 0..* | BackboneElement | Device capabilities |
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of capability Binding: MII VS MTB Panel Capability (required) |
![]() ![]() |
S | 0..1 | uri | Herstellerseite / Produktdokumentation |
![]() ![]() |
S | 0..* | Annotation | Device notes and comments |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceDefinition.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.type | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.capability.type | Base | required | MII VS MTB Panel Capability | 📦2027.0.0-ballot.1 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | DeviceDefinition | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | DeviceDefinition | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | DeviceDefinition | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | DeviceDefinition | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | DeviceDefinition | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Differential-Ansicht
Diese Struktur ist abgeleitet von DeviceDefinition
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | DeviceDefinition | An instance of a medical-related component of a medical device | |
![]() ![]() |
S | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() |
S | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..* | (Complex) | MII EX MTB Panel Gene List URL: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-ex-mtb-panel-gene-list |
![]() ![]() |
S | 0..1 | string, Reference(Organization) | Name of device manufacturer |
![]() ![]() |
S | 1..* | BackboneElement | A name given to the device to identify it |
![]() ![]() ![]() |
S | 1..1 | string | The name of the device |
![]() ![]() ![]() |
S | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other |
![]() ![]() |
S | 1..1 | CodeableConcept | What kind of device or device system this is Required Pattern: At least the following |
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/CodeSystem/mii-cs-mtb-genomicanalysis-devicefunction | |
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: gene-panel | |
![]() ![]() |
S | 0..* | string | Available versions |
![]() ![]() |
S | 0..* | BackboneElement | Device capabilities |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of capability Binding: MII VS MTB Panel Capability (required) |
![]() ![]() |
S | 0..1 | uri | Herstellerseite / Produktdokumentation |
![]() ![]() |
S | 0..* | Annotation | Device notes and comments |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceDefinition.capability.type | Base | required | MII VS MTB Panel Capability | 📦2027.0.0-ballot.1 | This IG |
Snapshot-AnsichtView
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
0..* | DeviceDefinition | An instance of a medical-related component of a medical device | |||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
SΣ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Version specific identifier | ||||
![]() ![]() ![]() |
Σ | 0..1 | instant | When the resource version last changed | ||||
![]() ![]() ![]() |
Σ | 0..1 | uri | Identifies where the resource comes from | ||||
![]() ![]() ![]() |
SΣ | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to | ||||
![]() ![]() ![]() |
Σ | 0..* | Coding | Security Labels applied to this resource Binding: All Security Labels (extensible): Security Labels from the Healthcare Privacy and Security Classification System. | ||||
![]() ![]() ![]() |
Σ | 0..* | Coding | Tags applied to this resource Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
S | 0..* | (Complex) | MII EX MTB Panel Gene List URL: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-ex-mtb-panel-gene-list | ||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
0..* | Identifier | Instance identifier | |||||
![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | string | The identifier that is to be associated with every Device that references this DeviceDefintiion for the issuer and jurisdication porvided in the DeviceDefinition.udiDeviceIdentifier | |||||
![]() ![]() ![]() |
1..1 | uri | The organization that assigns the identifier algorithm | |||||
![]() ![]() ![]() |
1..1 | uri | The jurisdiction to which the deviceIdentifier applies | |||||
![]() ![]() |
S | 0..1 | Name of device manufacturer | |||||
![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() |
Reference(Organization) | |||||||
![]() ![]() |
S | 1..* | BackboneElement | A name given to the device to identify it | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
S | 1..1 | string | The name of the device | ||||
![]() ![]() ![]() |
S | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | ||||
![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() |
S | 1..1 | CodeableConcept | What kind of device or device system this is Binding: FHIRDeviceTypes (example): Type of device e.g. according to official classification. Required Pattern: At least the following | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/CodeSystem/mii-cs-mtb-genomicanalysis-devicefunction | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: gene-panel | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | string | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() |
S | 0..* | string | Available versions | ||||
![]() ![]() |
Σ | 0..* | CodeableConcept | Safety characteristics of the device Binding: DeviceSafety (example) | ||||
![]() ![]() |
0..* | ProductShelfLife | Shelf Life and storage information | |||||
![]() ![]() |
0..1 | ProdCharacteristic | Dimensions, color etc. | |||||
![]() ![]() |
0..* | CodeableConcept | Language code for the human-readable text strings produced by the device (all supported) | |||||
![]() ![]() |
S | 0..* | BackboneElement | Device capabilities | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Type of capability Binding: MII VS MTB Panel Capability (required) | ||||
![]() ![]() ![]() |
0..* | CodeableConcept | Description of capability | |||||
![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() |
S | 0..1 | uri | Herstellerseite / Produktdokumentation | ||||
![]() ![]() |
S | 0..* | Annotation | Device notes and comments | ||||
![]() ![]() |
0..1 | Quantity | The quantity of the device present in the packaging (e.g. the number of devices present in a pack, or the number of devices in the same package of the medicinal product) | |||||
![]() ![]() |
Σ | 0..1 | Reference(DeviceDefinition) | The parent device it can be part of | ||||
![]() ![]() |
0..* | BackboneElement | A substance used to create the material(s) of which the device is made | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The substance | |||||
![]() ![]() ![]() |
0..1 | boolean | Indicates an alternative material of the device | |||||
![]() ![]() ![]() |
0..1 | boolean | Whether the substance is a known or suspected allergen | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceDefinition.meta.security | Base | extensible | SecurityLabels | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.meta.tag | Base | example | Common Tags | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.type | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.safety | Base | example | Device safety | 📍4.0.1 | FHIR Std. |
| DeviceDefinition.capability.type | Base | required | MII VS MTB Panel Capability | 📦2027.0.0-ballot.1 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | DeviceDefinition | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | DeviceDefinition | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | DeviceDefinition | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | DeviceDefinition | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | DeviceDefinition | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Diese Struktur ist abgeleitet von DeviceDefinition
Weitere Repräsentationen des Profils: CSV, Excel, Schematron